INTEC GmbH
Lift controller MLC 8000
22/12/2016
Operating manual V2.0
9.2 Parameter synchronization within a lift group
All parameters and thus also the input / output parameters of ESE modules of a lift controller
are stored in the EEPROM of the HSE Unit.
Since the group control must continue to work if individual lifts of the group are not in
operation, it is necessary to save the same ESE parameters in all lift controllers in this group.
Therefore, after changing parameters of an ESE module ,synchronization is required.
The menu item " Group sync." inside the main menu "Parameter" is started on the module at
which the ESE parameters have been changed. The HSE then sends the relevant
parameters to all other lifts of the group. It is important that the other lifts of the group are
turned on when you start the group synchronization.