Keyboard Commands - Intec MLC 8000 Operating Manual

Lift controller
Table of Contents

Advertisement

INTEC GmbH
Lift controller MLC 8000
22/12/2016
Operating manual V2.0
Lost connection
to HSE!
Continue with
any key!
By pressing ENTER ↵, the connection, if possible, can be reestablished.

1.2 Keyboard commands

For experienced users, there is next to the menu the so called keyboard commands used in
the operation of the lift controller, where a lot of time can be saved.
Certain functions or menu items can be selected by pressing the keyboard commands
directly, by passing the menu structure.
Each keyboard command consists of a sequence of digits that are acknowledged by
pressing the ENTER key ↵. The time interval between 2 consecutive keys must not be
greater than 3 seconds, otherwise the previously operated keys are invalid and the key
command must be started from the beginning. Operated key will be shown in the LCD
display on the bottom left
The keyboard commands can be used anytime, regardless of what is shown on the LCD
display of the lift controller or the hand-held terminal.
Only in a few menu items or functions the keyboard commands are disabled, for example, in
the menus "Travel commands" and "Door commands" or the "Hardware test".
The following table lists all the keyboard commands .
Kommando
0 ↵
State display 1
1 ↵
Open door 1
2 ↵
Open door 2
3 ↵
Open door 3
4 ↵
Close all doors
5 ↵
Enable /Disable door lock
6 ↵
Enable /Disable landing calls
7 ↵
Test drives on / off
8 ↵
Menu "Travel movement"
9 ↵
Save all parameters
0 0 ↵
Menu "Basic settings"
0 1 ↵
"Out of service" indication on/off
0 0 0 ↵
Menu "General parameters"
0 0 1 ↵
Menu "Timer parameter"
0 1 2 ↵
Menu "Error stack"
0 1 3 ↵
Menu "Error count"
0 1 5 ↵
Clear error stack
Bedeutung
12/196
Hinweise
Main screen