Intec MLC 8000 Operating Manual page 23

Lift controller
Table of Contents

Advertisement

INTEC GmbH
Lift controller MLC 8000
22/12/2016
Operating manual V2.0
1. Menu level
2. Menu level
Positions/Imp.
3. Menu level
4. Menu level
Read from drive
Write to drive
Dec./stop dist.
Dec. v3 ↑
Dec. v3 ↓
Dec. v2 ↑
Dec. v2 ↓
Dec. v1 ↑
Dec. v1 ↓
Stop ↑
Stop ↓
Dec.vZ2 ↑
Dec.vZ2 ↓
Dec.vZ1 ↑
Dec.vZ1 ↓
Min.Dist.v3
Min.Dist.v2
23/196
Description
The drive-specific parameters (see above) are each stored in both the
drive and in the lift controller. For the operation of the lift, the
parameters in the drive and control need to be the same
(synchronous) . If the parameters are changed in the lift controller,
then they are automatically sent also to the drive (synchronized).
However, if you change parameters directly on the CANopen lift drive,
then the changes need to be transferred manually with this menu item
from the drive to the lift controller.
If a CAN open drive has been replaced, then the drive parameters can
be sent with this menu item to the new drive, ie, the drive must not be
customized manually before.
In addition, this menu option is required if within the lift controller
drive-specific parameters (see above) were changed while the drive
(VVVF) was not switched on (not "available") .
All red marked parameters are automatically measured during the
setup trip and do not need to be changed.
Gemessene Brems- und Anhaltewege
Braking distance for speed v3 in the upward direction
Braking distance for speed v3 in the downward direction
Braking distance for speed v2 in the upward direction
Braking distance for speed v2 in the downward direction
Braking distance for speed v1 in the upward direction
Braking distance for speed v1 in the downward direction
Stopping distance in the upward direction
Stopping distance in the downward direction
Braking distance for speed vZ2 in the upward direction
Braking distance for speed vZ2 in the downward direction
Braking distance for speed vZ1 in the upward direction
Braking distance for speed vZ1 in the downward direction
Minimum distance between start and target floor to start with nominal
speed v3
Minimum distance between start and target floor to start with reduced

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents