Nr.
Error message
129/100 No conn. to COP
129/128 Overrun RS232
129/129 Offl.Err.RS232
129/130 Onl.Err.RS232
129/131 CRC error RS232
129/144 Overrun iModul
129/145 Offl.Err.iModul
129/146 Onl.Err.iModul
129/147 CRC error iModul
130/48
Mult. group no.
144/1
Min.pressure
144/2
Max.pressure
144/16
Overload
160/0
Drive error
161/0
Drive err.move
Description
- Frequently switching inputs
- Errors in the controller
software
No CAN bus data transmission
to TSE boards inside car
operation panel COP.
Possible reasons:
- TSE defective
- COP not connected
- CAN bus line disturbed
Data overflow on RS232
interface (too much incoming
data in short time)
Disturbing signals on RS232 in
offline mode
Disturbing signals on RS232 in
online mode
Invalid data received (wrong
checksum) on RS232
Data overflow on iModul
(Modem, Ethernet, ...)
Disturbing signals on iModul
(Modem, Ethernet, ...) in offline
mode
Disturbing signals on iModul
(Modem, Ethernet, ...) in online
mode
Invalid data received (wrong
checksum) on iModul
(Modem, Ethernet, ...)
There are 2 HSE modules with
the same group number in a lift
group
For hydraulic lifts: oil pressure
below the limit (input
"Min.pressure" activated).
For hydraulic lifts: oil pressure
above the limit (input
"Max.pressure" activated).
Lift overloaded
Fault signal from the drive at
standstill state.
Fault signal from the drive
while moving.
95/196
Lift controller reaction
Lift continues operation.
Internal test of data transmission
The lift continues, however,
landing calls and group control do
not work properly.
Emergency stop.
Back to normal operation if input is
deactivated again.
Emergency stop.
Back to normal operation if input is
deactivated again.
Only measured if lift is located in a
floor with open doors.
Back to normal operation if
overload input is off.
Error state.
Back to normal operation if fault
signal is deactivated.
Emergency stop.
Back to normal operation if fault
signal is deactivated.