Commisioning; Setup Mode; Testing Of Individual Input And Output Functions; Setup Of Car Doors - Intec MLC 8000 Operating Manual

Lift controller
Table of Contents

Advertisement

INTEC GmbH
Lift controller MLC 8000
22/12/2016
Operating manual V2.0

3. Commisioning

3.1 Setup Mode

During assembly, the controller is in setup mode. This is done by setting the parameter
"Setup ready" to the value "No" (menu group "General paramet.").
In setup mode, various monitoring functions of the lift controller are disabled. This makes it
possible, for example, to proceed the lift without connecting the trailing cable by the
emergency recall operation pushes (assuming that all components which are absolutely
necessary for moving the lift are connected and the safety circuit is closed) .
In setup mode, a very careful work is required due to the deactivation of some
security functions within the controller.
In particular, note that the lift in the setup mode at inspection control passes over the
end floors .

3.2 Testing of individual input and output functions

After assembly and wiring ,individual control functions can be tested via the hardware test. In
the hardware test menu (see detailed description in the chapter "Troubles shooting"),
individual control outputs can be set and thus the correct connection of the control
components are checked. At the same control inputs can be set manually and thus checked
within the hardware test, whether the lift controller detects these inputs correctly.
The handheld terminal DSE is especially helpful when testing and commissioning, because
the handheld terminal can be connected right on the inspection box (plug on the FVE) .

3.3 Setup of car doors

Before teach-in of the lift controller the function of the car doors must be checked.
A first inspection may also be carried out here through the hardware test menu (see above).
By manually setting of the outputs to close or open the door it can be tested here whether the
door is moving in the right direction; by manually pressing (if available) the mechanical limit
switch, it can be determined whether these are configured correctly.
A complete door test can then be performed using the Control Menu "Door commands".

3.4 Teach-in

3.4.1 Starting normal operation for lifts with magnetic switch positioning

For lifts with magnetic switch positioning no further calibration of the lift is required. Here,
only the parameter "Setup ready" is set to the value "Yes" and so the normal operation
starts.