INTEC GmbH
Lift controller MLC 8000
22/12/2016
Operating manual V2.0
1. Menu level
2. Menu level
Group sync.
Parameter backup
Receive Paramet.
Basic setting
3. Menu level
4. Menu level
Can1 [kBaud]
Can2 [kBaud]
Reload backup
Create backup
61/196
Description
can therefore happen that a large number of errors in the error stack
are stored and the actual causes can be overwritten.
no: If more than 1 ESE error occurs at the same branch just one
"general" error is reported in the error stack. ESEs with node ID > 32
are reported as "local" ESE (because this ESEs are mainly plugged in
control cabinet directly on HSE).
Current baud rate CAN bus 1 (control bus). Default 125 kBaud
Current baud rate CAN bus 2 (shaft bus). Default 125 kBaud
In a group of lifts all parameters for the landing boards ESE must be
stored identically in all control boards HSE of this group. So in case of
failure / shutdown of a lift another HSE can handle the initialization of
the floor nodes ESE.
Through "group synchronization" the parameters for the floor nodes
ESE will be transfer from the current HSE to all other HSE boards
within the group.
The group synchronization has to be carried out by the HSE board that
has the actual parameters for the floor nodes ESE.
A parameter backup which was created earlier is loaded from the
backup EEPROM into the actual EEPROM.
Reloading a backup copy is primarily intended for the case that on the
current parameter set (accidentally) important changes have been
made that can be undone through this again.
Attention! Reloading the back up copy only execute if a prior back up
copy was made.
Create a copy of the actual parameter set in the Backup EEPROM.
Making a backup copy should be done after setup is finished!
If parameters should be written from a PC (Lifcontrol software) to the
lift controller by remote data transmission (Telephone line, Ethernet /
Internet), then it is necessary for safety reasons that this menu item
will be started. Only then the HSE is ready to receive parameters.
Note: This item can not be started with the hand-held terminal function
of the PC software "Liftcontrol". It is therefore necessary to provide a
local person.
User interface for easy creating a basic set of parameters for a
particular lift.
To start the default setting, the input of the password is required
(protection against misuse).