Intec MLC 8000 Operating Manual page 47

Lift controller
Table of Contents

Advertisement

INTEC GmbH
Lift controller MLC 8000
22/12/2016
Operating manual V2.0
1. Menu level
2. Menu level
3. Menu level
4. Menu level
Slow ↑[mm]
Slow ↓[mm]
Check ↑[mm]
Check ↓[mm]
Clock run
ClearCall
CR1 Start[Std]
CR1 Stop [Std]
CR1 Parkfloor
CR1 Parkt.[s]
CR2 Parkfloor
CR2 Parkt.[s]
Call tables
LC config.1
1. Floor
2. Floor
...
CC config.1
1. Floor
2. Floor
...
47/196
Description
Distance from the top floor at which the reduced speed should be
switched
See above.; for lowest floor
Distance from the top floor at which the monitor input "Decel.check"
(usually switched by the special output "Shelter" - "v-limit" - see
above) must have switched.
See above.; for lowest floor
Parameters for clock run
on: all calls are cleared when the clock run starts
off: all calls are cleared when the clock run stops
on+off: all calls are cleared when the clock run starts and stops
no: calls are not cleared in the moment clock runs are activated or
deactivated.
start time for clock run 1 (only full hours adjustable)
end time for clock run 1 (only full hours adjustable)
Park floor while clock run 1 is active
If the lift is not used for this time and clock run 1 is activated the lift
will go to the specified parking level.
Park floor while clock run 2 is active
If the lift is not used for this time and clock run 2 is activated the lift
will go to the specified parking level.
Table with enabled doors and floors in operation mode „Call config."
(siehe „General paramet.")
Enabled doors and floors for landing calls if call configuration 1 is
active
Enabled doors in floor 1
Enabled doors in floor 2
Enabled doors and floors for car calls if call configuration 1 is active
Enabled doors in floor 1
Enabled doors in floor 2