Intec MLC 8000 Operating Manual page 181

Lift controller
Table of Contents

Advertisement

INTEC GmbH
Lift controller MLC 8000
22/12/2016
Operating manual V2.0
Position
Pin
Function
XU1
1
+24V
2
0(24V)
3
CAN+
4
CAN-
XU2
1
0(24V)
2
D1
3
D2
4
D3
5
D4
6
D5
7
D6
8
D7
9
D8
10
+24V
XU3
1
D1
2
D2
3
D3
4
D4
5
D5
6
D6
7
D7
8
D8
9
0(24V)
10
+24V
XU5
Connector for Software download
XU6
Jumper for setting of node ID:
Jumper not set (Version 1.0) or set to the right (PCB edge) (Version 2.0): Normal operation
Jumper set (Version 1.0) or set to the left (Version 2.0): Initialization mode (setting of node
ID)
JP1
Jumper for CAN bus terminator (JP5 for Version 1.0, JP1 for Version 2.0)
→ Jumper must be set if LCI16 is located at the end of the CAN bus cable.
bzw.
JP5
XU8
Demo mode (Jumper set)
XU7
Activation of onboard buzzer.
The function of the buzzer must be set by parameter in menu "Special parameter" - "Car
display".
LED
LED "Software is running"
+24V Power supply input
0V Power supply input
CAN-Bus – High signal
CAN-Bus – Low signal
0V Power supply for inputs / outputs
8 inputs / outputs E1-E8 and A1-A8, low active, free programmable.
Connector XU2 is in parallel to XU3 (same inputs/outputs)
+24V Power supply for inputs / outputs
8 inputs / outputs E1-E8 and A1-A8, low active, free programmable.
Connector XU3 is in parallel to XU2 (same inputs/outputs)
0V Power supply for inputs / outputs
+24V Power supply for inputs / outputs