Intec MLC 8000 Operating Manual page 182

Lift controller
Table of Contents

Advertisement

INTEC GmbH
22/12/2016
Technical specifications:
Temperature range:
Current in idle mode:
Max. input current D1-8:
Max. output current D1-8 (LCI16.1):
Max. output current D1-8 (LCI16.2):
Mechanical dimensions:
Characteristics and features:
-
Level indicator - blue segmented LCD display 2 characters with 16 segments each
-
Integrated overload display (overload symbol)
-
Integrated buzzer (programmable, for overload, door closing or call acknowledge)
-
Integrated non-smoking symbol (activation by parameter)
-
PIC18 microcontroller with internal Flash (32kByte), RAM (1536 Byte) and EEPROM (256 Byte)
-
integrated CAN controller
-
CAN interface with high-speed driver according to ISO11898 with galvanic isolation
-
ICSP interface for In-Circuit-Programming (Software download)
-
8 inputs and 8 outputs, always 1 input and 1 output onboard connected
-
LCI16.1: lowside switching inputs / outputs
-
LCI16.2: highside switching inputs / outputs
-
Even if always 1 input and 1 output are connected together the may be used for different
functions at the same time, because every active output is switched off every 9ms for 3ms (pulsed
output) to enable reading of the input in this time.
Example: Input used as car call, output used as level indicator
Lift controller MLC 8000
Operating manual V2.0
0°C to +60°C
ca. 50mA @
25°C
10mA @
25°C / Input
500mA @ 25°C / Output
350mA @ 25°C / Output
Length:
Width:
Height:
Active display:
Character height: 45mm
158mm
80mm
ca. 30mm (without connector)
130*61mm