Intec MLC 8000 Operating Manual page 157

Lift controller
Table of Contents

Advertisement

INTEC GmbH
Lift controller MLC 8000
22/12/2016
Operating manual V2.0
Position
Function
RC1/
SLOW
DOWN
FAST
V2*, V2
XM5
L-SAF
N-SAF
SDSL
CDSL
RDSL
PSL
N
CSUP
XM6
+24S
0V
ZONE
MSI
ULSI
n.c.
n.c.
SRO
XM7
0V
+24A
+24C
XM8
0V
+24IN
XM9
+12V
0V
0V
BA+
XM10
Connector for handheld terminal (No USB connector!)
XM11
0V
C1-
C1+
XM12
0V
0V
C2-
C2+
XM13
0V
B+
B-
Relay KM3 (MCU Output 3): N.O. contact; Default: Main contactor (Running
contactor)
Note: For lifts with safety unit for moving with open doors the relay KM3 must
always be used as running contactor even if nothing is connected to KM3,
because by a second contact of KM3 the door zone bypass will be enabled.
Relay KM2 (MCU Output 2): N.O. contact; Default: Downwards contactor
Relay KM1 (MCU Output 1): N.O. contact; Default: Fast contactor
Relay KM1 (MCU Output 1): Additional, potential free N.O. contact
Connection for end of safety circuit to switch contactors
Neutral safety circuit (Output to connnecting neutral to contactors)
State input safety line shaft doors (MCU Input 12), for 110V to 230V AC
State input safety line car doors (MCU Input 11), for 110V to 230V AC
State input safety line revolving shaft doors (MCU Input 10), for 110V to 230V
AC
State input primary safety line (MCU Input 9), for 110V to 230V AC
Neutral safety circuit (Input)
Input for contactor supervision (MCU Input 13), for 110V to 230V AC
24V power supply output to safety unit SRU; Imax.=0.5A (electronic fuse on
MCU).
0V power supply for safety unit SRU
Feedback signal from safety unit SRU (lift in door zone)
Output door zone switch MSI to safety unit SRU channel A
Output 2. door zone signal to safety unit SRU channel B (generated by
software, logical OR of USI and LSI signals)
Not connected
Not connected
Safety circuit door zone bypass for moving with open doors (output of safety
unit SRU)
0V – Power supply (to trailing cable)
Battery buffered 24V power supply (to trailing cable); Imax. = 1.0A (electronic
fuse on MCU)
24V – Power supply (to trailing cable); Imax. = 1.8A (electronic fuse on MCU).
If larger power is necessary the trailing cable should be connected directly to
the 24V power supply unit.
0V – Power supply input for MCU
+24V – Power supply input for MCU
Battery buffered 12V - Power supply (e.g. for Intercom); Imax. = 0.5A; overload
and short-circuit-proof
0V – Power supply
0V – Connection for negative pol of external 12V battery
Connector for positive pol of external 12V battery (battery charging)
Connetor for shield CAN bus cable (only MCU version 1.2)
Control bus (CAN-Bus 1) – Low-Signal
Control bus (CAN-Bus 1) – High-Signal
0V – Power supply
Connetor for shield CAN bus cable
Shaft bus (CAN Bus 2) – Low-Signal
Shaftbus (CAN Bus 2) – High-Signal
0V – Power supply for encoder
Encoder Channel B+; 5V oder 10..30V (see Jumper JP4+JP5)
Encoder Channel B- (inverted signal); 5V or 10..30V (see Jumper JP4+JP5)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents