Intec MLC 8000 Operating Manual page 81

Lift controller
Table of Contents

Advertisement

INTEC GmbH
Lift controller MLC 8000
22/12/2016
Operating manual V2.0
Module
HSE control module, which has diagnosed the error
State
Moving Controller state when the error occurred
Trips
16391 Trip counter when the error occurred
Set speed
v3 Selected lift speed:
Dir.
Upwards Selected lift direction ("Upwards" , "Downwards" or 0 at Standstill)
Drivest.Standst. State of drive controller:
Floor
3 Actual floor
Pos.
9312 Actual position in mm
Speed
1200
O.1- 8
■□■□■□□□ State of outputs 1-8 of HSE(from left, ■ = output is set)
I.1- 8
□□■□□□□■ State of inputs 1-8 of HSE(from left, ■ = input is set)
■□■□■□□□ State of inputs 9-16 of HSE(from left, ■ = input is set)
I.9-16
Calls
enabled Calls enabled/disabled
LC
disabled Landing calls enabled/disabled
Start fl.
3 Start floor of actual / last trip
Target fl.
6 Target floor of actual / last trip
■■■□ State of safety line (from left):
SL 1-4
0 at standstill
„vRL": Re-levelling speed
„v0": Arrival speed
„v1":Intermediate speed 1 (for short floor distances)
„v2":Intermediate speed 2 (for short floor distances)
„v3": Nominal speed
„vI": Normal Inspection speed
„vIS": Slow Inspection speed
„vR" : Fast Electrical recall operation speed
„vRS" : Slow (normal) Electrical recall operation speed
„vEE(UPS)": Evacuation speed (UPS Evacuation)
„vHu": Lift with holding bolts: Up speed from holding bolts
„vHd": Lift with holding bolts: Down speed to holding bolts
„vZ1": Additional intermadiate speed 1
„vZ2": Additional intermadiate speed 2
„Stopped"
„Start"
„Enable"
„Star/Delta"
„Softstarter"
"Targ.ack"
„Op.Brake"
„Moving"
„Slowing"
„Stopping"
„Cl.Brake"
„Sw.off"
If the calibration process has not been completed or a required reference
movement has not yet been carried out, then here "-" is displayed.
Reference position is lowest floor (= 0)
If the calibration process has not been completed or a required reference
movement has not yet been carried out, then here "-" is displayed.
Actual speed in mm/s
- Primary safety circuit