1. Menu level
2. Menu level
3. Menu level
4. Menu level
LC config.2
1. Floor
2. Floor
...
CC config.2
1. Floor
2. Floor
...
LC-config.3
...
...
En/Disable calls
Disable
Enable
Autom.CC
Autom.LC
Clear Call
Priority
48/196
Description
Enabled doors and floors for landing calls if call configuration 2 is
active
Enabled doors in floor 1
Enabled doors in floor 2
Enabled doors and floors for car calls if call configuration 2 is active
Enabled doors in floor 1
Enabled doors in floor 2
Enabled doors and floors for landing calls if call configuration 3 is
active
Parameters for enabling / disabling doors and floors
normal: When an input is activated for disabling of calls or doors, then
only "normal" calls are affected
+special: Through an active input for disabling of doors or calls both
"normal" calls and special calls are affected
normal: When an input is activated for enabling of calls or doors, then
only "normal" calls are affected
+special: Through an active input for enabling of doors or calls both
"normal" calls and special calls are affected
yes: If an input is activated to enable a car call for a floor or door, then
a car call for the appropriate floor and door is automatically set in this
moment.
yes: If an input is activated to enable a landing call for a floor or door,
then this landing call is automatically set in this moment.
yes: When setting an input for disabling a car call, an already existing
car call for this floor is cleared.
Disable: If for one call, at the same time, an input was given to enable
this call and an input to disable this call, then the disable input has
priority .
Enable: If for one call, at the same time, an input was given to enable
this call and an input to disable this call, then the enable input has

Hide quick links: