Intec MLC 8000 Operating Manual page 37

Lift controller
Table of Contents

Advertisement

INTEC GmbH
Lift controller MLC 8000
22/12/2016
Operating manual V2.0
1. Menu level
2. Menu level
3. Menu level
4. Menu level
Run to fire
Parking trip
Park mode
Park floor
Parktime[s]
Zone 1 Start
Zone 1 Stop
Zone 2 Start
Zone 2 Stop
....
Zone 8 Start
Zone 8 Stop
Mand.zones
Visitor calls
CC enabl.[s]
LC enabl.[s]
37/196
Description
no).
If set to "yes" emergency trips have higher priority than fire alarm
control (see below)
Indicates whether the floors can be reached in which a fire alarm is
active (yes / no)
Parameters for park ride
Fixed: The lift goes to a fixed Park Floor
Zones: The lift is parked in the pre-defined zones (mainly for lift
groups)
Park floor if park mode is "Fixed"
(Note: Up to version 1.32y this parameters is displayed in the menu
"General parameter")
If the lift is not used for this time the lift will go to the specified parking
level.
(Note: Up to version 1.32y this parameters is displayed in the menu
"Timer parameter")
Bottom floor of the parking zone 1
Top floor of the parking zone 1
Note: If the top floor value is less than the bottom floor value, then the
parking zone is disabled
See above
See above
See above
See abov
Specifies how many parking zones (starting with zone 1) must be
filled.
Example: In a group lift 1 is parked within zone 1 and lift 2 is parked in
zone 2. If lift 1 is called to another floor and the value of "Mandatory
zones" is> 0, then lift 2 goes to zone 1 and parks there. If the value
"Mandatory Zone = 0 he would remain in Zone 2.
Parameters for visitors calls and visitor control
Time period car calls are enabled after the lift was sent to a floor by a
visitor call (type 1 and type 2)
Time period landing calls are enabled after a visitor call (type 1 and
type 3) was set.