1. Menu level
2. Menu level
3. Menu level
4. Menu level
Closeattempts
Rev.del.[ms]
Cls.delay[s]
Relays
MaxCl.Rel[s]
MaxOp.Rel[s]
29/196
Description
new call to another floor. This process can only be repeated according
to the number set here. If the door cannot be opened after that
number of attemps, the lift goes out of service.
If the value 0 is set, there is an unlimited number of opening attempts.
Number of door close attemps
Here it is set how often the lift controller tries to close the door before
the lift goes out of service.
If the value 0 is set, there is an unlimited number of closing attempts.
Waiting time between changing the direction of the movement of the
door
Waiting time between a door closing command of the liift controller
and the actual closing of the door.
Within this waiting time, for example, a warning (acoustic / optical
signal) can take place
Switching status of the door close relay after the door is completely
closed or of the door open relay after the door is fully opened.
- both on: The door close relay remains on after the door is completely
closed; the door open relay remains energized after the door is fully
opened
- both off: Once the door is fully opened or closed, the door close
relay and door open relay are switched off
- Open on: The door open relay remains energized after the door is
fully opened; but the door close relay is switched off after the door is
completely closed.
- Close on: The door close relay remains energized after the door is
fully closed; but the door open relay is switched off after the door is
completely opened.
Only relevant if the "relay" parameter (see above) is set to "both on",
or "Close on":
Here a maximum time can be set for the door close relay to remain
switched on. At standstill, the relay switches off after this time (e.g. to
prevent overheating the door motor)
If this value is set to 0, then the door close relay is always turned on
when the door is closed.
Only relevant if the "relay" parameter (see above) is set to "both on",
or "Open on":
Here a maximum time can be set for the door open relay to remain
switched on. At standstill, the relay switches off after this time (e.g. to
prevent overheating the door motor)
If this value is set to 0, then the door open relay is always turned on

Hide quick links: