Intec MLC 8000 Operating Manual page 190

Lift controller
Table of Contents

Advertisement

INTEC GmbH
Lift controller MLC 8000
22/12/2016
Operating manual V2.0
XL3
1
D1
2
D2
3
D3
4
D4
5
D5
6
D6
7
D7
8
D8
9
0(24V)
10
+24V
XL4
Connector for Software download
XL6
SD card slot
XLJ1
Jumper for CAN bus terminator
→ Jumper must be set if LCD-047 is located at the end of the CAN bus cable.
XLJ2
Jumper for setting of node ID:
Jumper set to the PCB edge: Normal operation
Jumper set to the PCB centre: Initialization mode (setting of node ID)
K1
Button to active design selection menu: With this menu it is possible to select one of 4
designs saved inside LCD-047. Selection is done with button K2 (cursor up) or button K3
(cursor down), activation by pressing button K1 again.
K2
Button to activate colour selection menu. With this menu the colour of direction arrows, floor
signs and date / time may be set (blue, yellow, black, white, grey, red or green).
Additionally it can be selected if the direction arrows should scroll if the lift is moving.
Selection of a menu item is done by pressing button K3 (cursor down), changing of selected
setting is done by pressing button K1. Activation of settings is done by pressing button K2
again.
K3
Button to navigate inside menus (cursor down, see above)
LED
LED "Software is running"
Characteristics and features:
-
Car level display - LCD graphic display with 480*272 Pixel, 24 Bit colour depth
-
4 different configurations (designs) free selectable (saved inside LCD-047)
-
horizontal and vertical orientation possible
-
Creation of configurations (designs) possible with PC-Software "LCDDesign"
-
Display for:
Car level signs (two digits)
Floor pictures (free configurable size)
Direction arrows
Special functions
Overload
Date and time
-
Downloading of new designs to LCD-047 by SD memory card
-
Integrated overload buzzer
-
powerful ARM7 32 bit microcontroller
-
128 MByte NAND-Flash memory for designs
-
integrated CAN controller
-
CAN interface with high-speed driver according to ISO11898 with galvanic isolation
-
JTAG interface for In-Circuit-Programming (Software download)
-
Energy saving mode (Standby - Backlite off) possible (selectable by lift controller parameter
"Energy savings")
-
8 inputs and 8 outputs, always 1 input and 1 output onboard connected (lowside switching)
-
Even if always 1 input and 1 output are connected together the may be used for different
functions at the same time, because every active output is switched off every 9ms for 3ms (pulsed
output) to enable reading of the input in this time.
8 inputs / outputs E1-E8 and A1-A8, low active, free programmable.
Connector XL3 is in parallel to XL2 (same inputs/outputs)
0V Power supply for inputs / outputs
+24V Power supply for inputs / outputs