Intec MLC 8000 Operating Manual page 96

Lift controller
Table of Contents

Advertisement

INTEC GmbH
Lift controller MLC 8000
22/12/2016
Operating manual V2.0
Nr.
Error message
161/1
No Ready signal
161/2
No Brake signal
161/3
Ready sign.n.off
161/4
Brake sig.n.off
161/5
RB/contac. off
161/6
Brake=0 on move
161/7
Mov.=0 on run
161/8
Softst=0 on run
161/9
No Softst.signal
161/10
RB/contact.on
161/11
Brakesig.not off
161/12
Softst.not off
161/13
CAN:TimeoutBrake
161/14
CAN:Timeout VoEn
Description
The "Ready" signal from the
drive is not activated on time.
The "Brake" signal from the
drive is not activated on time.
The "Ready" signal from the
drive is not deactivated on
time.
The "Brake" signal from the
drive is not deactivated on
time.
The feedback signal from
running contactors is
deactivated while the lift is
moving.
The "Brake" signal from the
drive is deactivated while the
lift is moving.
The "Moving" signal from the
drive is deactivated while the
lift is moving.
The "Ramp end" signal from
the softstarter (hydraulic lifts) is
deactivated while the lift is
moving.
The "Ramp end" signal from
the softstarter (hydraulic lifts) is
not activated in time.
The feedback signal from the
running contactors is not
deactivated after the trip is
finished.
The "Brake" signal from the
drive is activated while the lift is
in standstill state.
The "Ramp end" signal from
the softstarter (hydraulic lifts) is
activated while the lift is in
standstill state.
Only by drives according to
CANopen lift DSP417:
No message to open the brake
in time.
Only by drives according to
CANopen lift DSP417:
No message to apply power to
the motor ("Voltage Enable") in
time.
96/196
Lift controller reaction
Emergency stop.
Back to normal operation inside 2
seconds.
Emergency stop.
Back to normal operation inside 2
seconds.
Emergency stop.
Back to normal operation inside 2
seconds.
Emergency stop.
Back to normal operation inside 2
seconds.
Emergency stop.
Back to normal operation inside 2
seconds.
Emergency stop.
Back to normal operation inside 2
seconds.
Emergency stop.
Back to normal operation inside 2
seconds.
Emergency stop.
Back to normal operation inside 2
seconds.
Emergency stop.
Back to normal operation inside 2
seconds.
Back to normal operation if the
signal is deactivated.
Back to normal operation if the
signal is deactivated.
Back to normal operation if the
signal is deactivated.
Emergency stop.
Back to normal operation inside 2
seconds.
Emergency stop.
Back to normal operation inside 2
seconds.