Intec MLC 8000 Operating Manual page 92

Lift controller
Table of Contents

Advertisement

INTEC GmbH
Lift controller MLC 8000
22/12/2016
Operating manual V2.0
Nr.
Error message
96/0
SW error
97/0
Int.SW error
oder
Lift WD-Reset
97/1
Lift Boot up
97/2
Restart xxx
(xxx = PCB name)
97/3
ASE Softw.<1.40
97/4
FVE Softw.<1.40
97/5
Lift SW-Reset
97/6
Lift HW-Reset
98/1
Group param.
98/2
Drive param.
Description
code) is located on the CAN
bus.
Error in the internal program
sequence of HSE, probably
triggered by EMC interference
or for example cold solder
joints on the PCB.
Internal software error of a
module, triggering the
"watchdog timer"; software
restart.
See above.
Lift restart after power on
Software restart of a module
during operation (for example,
when you connect an ESE
module to a running lift).
Due to changes in the
CANopen standard, there are
compatibility issues when using
HSE modules with version from
1.32n and ASE modules older
than version 1.40 This error
message also sometimes
occurs due to EMC problems -
see errors above.
See above
Reset HSE was performed by
software (with keypad of HSE
or handheld terminal)
Reset HSE was performed
(with Reset button on HSE)
In a group of lifts the
parameters for shaft bus PCBs
ESE are not identical in all lifts.
Only for lifts with drives
92/196
Lift controller reaction
(see chapter "Hardware
encoding").
Check EMC-compliant wiring of the
lift, replace HSE if necessary.
Emergency stop, re-initialization of
the module, then return to normal
operation.
If this error occurs at a TSE or
ESE-module, then the re-
initialization is done during
operation, ie, with no emergency
stop.
Check EMC-compliant wiring of the
lift, replace PCB if necessary.
Lift starts reset trip (if setup is
already finished)
Emergency stop, re-initialization of
the module, then return to normal
operation.
If this error occurs at a TSE or
ESE-module, then the re-
initialization is done during
operation, ie, with no emergency
stop.
Lift is not running; HSE must be
changed to older version or ASE to
version 1.40 or newer..
Lift is not running; HSE must be
changed to older version or FVE to
version 1.40 or newer..
Start menu item „Group sync"
To synchronize drive parameters