Menu Structure - Intec MLC 8000 Operating Manual

Lift controller
Table of Contents

Advertisement

INTEC GmbH
Lift controller MLC 8000
22/12/2016
Operating manual V2.0

2. Menu structure

1. Menu level
2. Menu level
Parameter
General paramet.
3. Menu level
4. Menu level
No.
Lift type
Bottom floor
Top floor
Group size
Group number
Car door numb.
Main floor
Park floor
Type
Setup ready
Push control
Call config.
16/196
Description
Lift number (for information only)
Rope / Hydraulic
Bottom floor
Top floor
Number of lifts per group (1 ... 8)
Number of lift within a group (1 ... 8)
Car door number (1 ... 3)
Main floor
Park floor
(Note: Starting with version 1.32z this parameter is in a separate
submenu "Special parameter" - "Parking trip")
Collecting control / Single call control
This value is set to "Yes" if setup is completed. As long as this value
is set to "No", all position values are invalid and the lift does not
handle trips (only electrical recall operation and inspection possible)
If set to "Yes" lift is working as a "Push control", ie, the lift only goes
as long as special pushs are pressed (also called Deadman control).
Note: As of version 1.36m HSE, this parameter is in the submenu
"special parameters" - "Push control "
If set to "Yes" special "call tables" (see "Special parameter") are
activated. If the lift arrives a floor by a landing call, only car calls
enabled for this landing call ("Call table" will be handled.
A maximum of 5 different call configurations can be set. Switching
between the Call configurations occurs only when all doors are closed
and (if available), the presence sensor signals "Car empty" signals
that no one is inside the car anymore.
In principle, up to 5 "logical" lifts can be created for one "real" lift , in
which only floors or entrances within this "logic" lift can be
approached.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents