Password Protection (Code); Menu Code; Parameter Code; Exceptions - Intec MLC 8000 Operating Manual

Lift controller
Table of Contents

Advertisement

INTEC GmbH
Lift controller MLC 8000
22/12/2016
Operating manual V2.0
Kommando
3: Relay KH13
... to Relay KH42
9: Output KH5
Switch off output HSE (siehe
9 x x ↵
above)

1.3 Password protection (Code)

The lift controller MLC 8000 has a two-stage access protection (code number). If access
protection is enabled, then when you start the menu structure (pressing ENTER ↵) you will
be asked to enter a numeric code.
Within the control 2 different access codes (Menu code, parameter code) can be stored.
These can be activated, changed or disabled (by setting the codes to 0) in the menu item
"Change password".
After entering a valid password access for 15 minutes is enabled, then the access is blocked
again and the State display 1 (main screen) is displayed.
The access time of 15 minutes starts again when:
- a key is pressed on the HSE or the hand-held terminal
- the lift is in "Teach in mode"
- The menu item "Travel commands" was started
- The menu item "Door command" was launched
- The menu item "Basic settings" was started

1.3.1 Menu code

If the menu code is activated, the menu structure can only get started if the corresponding
code has been entered.

1.3.2 Parameter code

If the parameter code is activated, the following actions can be performed only when the
appropriate code has been entered:
-
Changing parameters
-
Teach-in trip
-
Door movements with keyboard
-
Drive movement on keyboard
-
Basic settings
-
Group synchronization

1.3.3 Exceptions

Regardless of the preset or entered code following actions can always be carried out:
-
Display of state images
-
Input of calls over short commands
Start menu "Technical check" with short command 490 ↵
-
Bedeutung
14/196
Hinweise
e.g.: 905 ↵ = Output 5 (KH15) deactivated

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents