Intec MLC 8000 Operating Manual page 134

Lift controller
Table of Contents

Advertisement

INTEC GmbH
Lift controller MLC 8000
22/12/2016
Operating manual V2.0
Main function
Sub function/
Direction/
Floor
- Roomtemp.min
- Roomtemp.max
Fan temp.
Oil temp.
Conn.IO
Floor
Doors
-
-
-
-
-
-
Signal no.
-
134/196
Description
Machine room temperature sensor
Temperature sensor for switching the motor fan
Temperature sensor for oil temperature.
If this input is acive (oil is too cold), than the lift carries out oil warming trips after
a programmed time interval.
For time interval see parameter group "Oil warming".
The function "Connected IO" is used to virtual connect an input on any PCB
inside the lift controller to several outputs on different PCBs of the lift controller
without any wiring.
It is possible, for example, to program an input of the car top board FVE, where a
shaft light button is connected, as "Conn.IO", Signal no. 1.
By program an output relay of the HSE as "Conn.IO", Signal no. 1, this relay may
switch the shaft light without any wiring inside the trailing cable.
Up to 8 connections are possible inside a lift controller.

Hide quick links: