Intec MLC 8000 Operating Manual page 124

Lift controller
Table of Contents

Advertisement

INTEC GmbH
Lift controller MLC 8000
22/12/2016
Operating manual V2.0
Main function
Sub function/
Direction/
Floor
Emerg. run
Hazard run
Lift off
Lift off disp
Door op.push
Door cl.push
Dr.stop push
Presence.sen..
Clear calls
LC off
Remote off
Interm.door
Clock run 1
Floor
Doors
-
-
-
-
-
-
-
-
Floor (only
Doors
if set on ESE
input)
Floor (only
Doors
if set on ESE
input)
Floor (only
Doors
if set on ESE
input)
Floor (only
Doors
if set on ESE
input)
-
-
-
-
Floor
Doors
-
-
-
-
124/196
Description
Emergency run (landing calls off - only car calls active)
More settings see „Special param." – "Emerg. run adj."
Hazardous good transportation function
More settings see„Special param." – "Hazard transport"
Switching off the lift in current / next floor
Input for activating the "Out of order" display (e.g. for maintenance activities)
Door open push
More settings see „Door parameter – Gener.door para."
Door close push
More settings see „Door parameter – Gener.door para."
Door stop push (for keep door open e.g. for loading / unloading)
Anteroom surveillance to extend the door open time
(if passengers are waiting for the lift)
Push input to clear all calls
Disable all landing calls
Remote switch off lift
First lift goes to the floor programmed with this input and opens the door.
Second the lift goes to the floor programmed in „Special param. – Remote off"
and goes out of operation.
Switch on intermediate door.
If intermediate door is open the lift may only be used in special run mode (key
switch) or any other special control with higher priority (VIP run, ...)
Input to start clock runs.
More settings see „Special param." – "Clock run" and also "Door releases"
Note: The clock run 1 may be activated by this input as well as by the internal
timer (see „Special param." – "Clock run")