Intec MLC 8000 Operating Manual page 69

Lift controller
Table of Contents

Advertisement

INTEC GmbH
Lift controller MLC 8000
22/12/2016
Operating manual V2.0
1. Menu level
2. Menu level
Brake/valv.check
Runn. contactor
Open door safety
Uncontr.movement
Battery check
Reset HSE
Teach in trip
Sub menus if Positioning system with incremental encoder
3. Menu level
4. Menu level
Brake 1
Brake 2
Brake 3
On in standstill
Brake 1
Brake 2
Up valve
...
Off on trip
...
On by stop
...
Upward dir.
Downward dir.
Example:
Voltage
69/196
Testing the brake or valve supervisio contacts
Testing the supervision contact while lift is standstill
Selecting a contact for testing
T Testing the supervision contact while lift is moving
Testing the supervision contact at trip end
Test of mains contactors supervising.
It can be defined, which relay of the HSE should remain on after trip
Test of safety circuit for moving with open doors
Test UCM (uncontrolled movement)
Test in upward direction
Test in downward direction
Manual start of a battery test.
Note: The battery test is also performed automatically at the set time
interval (default is 24 hours).
12850 mV
Up to software version 1.38a this menu item is located directly in the
Perform a software reset of the HSE.
Calibration of the lift during commissioning.
Depending on the type of the positioning system (incremental or
absolute encoder) different sub menu items appear here.
Note: If conventional positioning with switches only is used a teach-in
Description
Switch off brake 1
Switch off brake 2
Switch off brake 3
end.
main menu.
trip is not required.