Operating manual V2.0
Position
Terminal no.
Description
3
KF1/2
4
GND
5
EF4
6
GND
7
EF3
8
GND
9
EF2
10
GND
11
EF1
XF14
1
GND
2
EF18
XF15
1
CHA
2
CHB
3
+24A
4
GND
XF16
1
GND
2
In
3
+24V
XF17
1
Res1
2
Res2
3
Res3
XF18
1
+24A
2
SM
3
SU
4
SO
5
VO
6
VU
7
0(24V)
8
0(24V)
9
+24V
10
+24V
XF19
1
NR
2
EAF10
3
EAF11
4
EAF12
5
EAF13
6
EAF14
7
EAF15
8
EAF16
9
GND
10
+24V
11
NL
12
+24A
13
M
14
L
XF20
1
NR
2
EAF9
3
EAF10
Function
Common for N.O. contact relays KF1 and KF2
Input E4 and 0V power supply, free programmable, default: Light screen
door 1
Input E3 and 0V power supply, free programmable, default: Reverse switch
door 1 (mechanical obstacle)
Input E2 and 0V power supply, free programmable, default: Door closed
limit switch door 1
Input E1 and 0V power supply, free programmable, default: Door opened
limit switch door 1
Input E18 and 0V power supply, free programmable, default: Overload
signal
Connectors for incremental encoder channel A and B (direct connected to
XF1.7+8)
Battery buffered +24V power supply for incremental encoder
0V power supply for incremental encoder
Connectors for analog load sensor and power supply +24V, sensor signal
see Jumper XFJ4+5 above
Free connectors for additional trailing cable wires; onboard connected to
XF17.Res1-3
Battery buffered 24V power supply for Position unit KLST GmbH (flat cable)
Door zone switch SGM of Position unit KLST GmbH (flat cable)
Inputs E25, E24, E26, E27 (low active), for door zone switches SGU and
SGO and for prelimit switches VO and VU (Position unit KLST GmbH over
flat cable)
0V power supply for Position unit KLST GmbH (flat cable)
24V power supply for Position unit KLST GmbH (flat cable)
Alarm call car operation panel COP (for flat cable connection of COP)
7 Inputs/Outputs E10-E16 and A10-A16
Low active, mainly for car operation panel COP (for flat cable connection of
COP)
Note: Inputs/outputs are also available on connector XF11
0V – power supply for car operation panel COP (for flat cable connection of
COP)
+24V power supply for car operation panel COP (for flat cable connection of
COP)
Emergency light in car operation panel COP (FVE output A7, for flat cable
connection of COP)
Battery buffered +24V power supply for car operation panel COP (for flat
cable connection of COP)
Intercom microphone (for flat cable connection of COP)
Intercom loudspeaker (for flat cable connection of COP)
Alarm call car operation panel COP, flat cable to TVE
8 Inputs/Outputs E9-E16 and A9-A16
Low active, mainly for car operation panel COP (flat cable to TVE)