1. Menu level
2. Menu level
Errors
Error stack
Error count
Clear stack
Clear count
Hardware test
HSE In-/Outputs
Bus node test
3. Menu level
4. Menu level
Example:
HW:1.01 SW:1.13
Eee--rudSSSs-nVZ
SGM: 1
Sdlube--
Example:
Bus nodes:
62/196
Description
Display all entries in the error stack (last 100 errors with time stamp)
Note: By pressing ENTER the error on which the cursor is currently
located, will display detailed information (see section "Error stack")
Display all entries of the error counter (frequency of each error)
Clear the entire error stack
Clear the entire error counter
Hardware test of each control module.
Capital letters at the inputs / outputs indicate that the input / output is
set, by lowercase letters ,the input / output is not set.
The letters represent a short code for the function of the input / output.
By positioning the cursor on an output, and pressing the '0' key, the
state of the output for test can be changed for test purposes (switch
on / off the output).
Attention: Even while the lift is running this function is possible!
Therefore, think about the possible consequences before carrying out!
For the first 8 outputs of a circuit board, the outputs can be directly
set / reset by pressing the corresponding number key.
By positioning the cursor on an input or output and pressing ENTER
detailed informations about the input / outpunt function are displayed
and may also be changed here.
Indication of the state of the inputs and outputs of the HSE; setting
outputs of HSE
1st line: Display of the hardware and software version
2nd line: state of the inputs of the HSE
3rd line: state of the door zone switch SGM
4th line: state of the outputs of the HSE
Here it is displayed whether the communication link (CAN bus, RS485
...) to the main control modules (FVE, ASE, PSE) works well or not.
Here are all control main modules displayed, which, depending on the
parameter settings, must be present.
If the communication to a module functions, then the software version
number after the module is displayed, otherwise '-' appears .