Intec MLC 8000 Operating Manual page 50

Lift controller
Table of Contents

Advertisement

INTEC GmbH
Lift controller MLC 8000
22/12/2016
Operating manual V2.0
1. Menu level
2. Menu level
3. Menu level
4. Menu level
Locked
Enable time[s]
Waitt.up[s]
Waitt.dn[s]
If clock run
If Special
Auto-call func.
Call dir.
Car calls
Land.calls
Oil warming
Time [min]
Floor
Start day
Start month
Stop day
Stop month
Dec.extens. ↑
50/196
Description
After a forced stop the lift only continues travellings in the specified
direction once a special input is activated (Funktion: Special fct.,
Subfunktion: Forc.stop off).
If, after a forced stop, a release is required for further travel (see
above), then it is set here how long the release button remains active
after you press.
If enable (input "forced stop off") is required (see above): After a
forced stop all calls are cleared after this waiting period, if no enable
signal is given.
If no enable signal is required (see above): Here, an additional waiting
time can be set for a forced stop. Upon pressing the enable button
("forced stop off"), the waiting time is disabled.
This parameter defines whether during clock run a forced stop is
performed (yes / no)
This parameter defines whether during a special trip a forced stop is
performed (yes / no)
Parameters for the auto-call function
upwards: The lift stops in the upward direction on each floor one after
the other and then moves from the top floor directly to the bottom
floor
downwards: The lift stops in the downward direction on each floor one
after the other and then moves from the bottom floor directly to the
top floor.
up+down: The lift goes first in upward direction and then in downward
direction each floor one after another.
Setting if car calls enabled in auto-call function
Setting if landing calls enabled in auto-call function
Time in minutes after which an oil heating trip is started
Target floor for oil warming trip
Time period, in which independent oil heating trips get performed. If
both, start and stop date, are identical, then the oil heating trips are
disabled.
Increased slow down distance for oil warming trip in upwards
direction.