INTEC GmbH
Lift controller MLC 8000
22/12/2016
Operating manual V2.0
1. Menu level
2. Menu level
CANopen
Set clock
Day
Month
Year
Hour
Minute
Second
Weekday
Start clock
Travel commands
Up<1>-Dn<3> VR
Up<4>-Dn<6> VRS
Exit with <ENT>
Safety line off
Door commands
3. Menu level
4. Menu level
Ready: ENT
Calibration
Nom.Ld.[kg]
Load[kg]
Start calibr.
Zero calibr.
67/196
Description
load).
The bar graph is calibrated for use with analog sensor from
Pulsotronic or 9914-0502 bzw. 9914-1002 - here the sensor should be
adjusted by empty car in a way that the bar graph is 0.
Calibration of load sensor should be done (if possible) with nominal
load.
The sensor value by nominal load should be not greater than 80% (if
sensor value increases with higher load) or 20% (if sensor value
decreases with higher load).
Note: Before starting calibration make sure the parameter "General
paramet. - Nom.Ld.[kg]" is set right.
Nominal lift load
This value is also displayed in "General param."
Loading of the car with a defined load. By inputting this load value, the
characteristic curve of the load sensor is calibrated.
Start of the calibration
Settings for load sensor with CANopen interface
Zero load adjustment (car must be empty)
Set real time clock of HSE
Set day
Set month
Set year
Set hour
Set minute
Set seconds
Set week day
Start real time clock with the settings above.
Travel movements by keypad.
By pressing and holding the relevant button the lift will go upwards or
downwards with the selected speed.
In line 4 a possible error will be displayed.
Door movement controlled by keypad