Intec MLC 8000 Operating Manual page 186

Lift controller
Table of Contents

Advertisement

INTEC GmbH
Lift controller MLC 8000
22/12/2016
Operating manual V2.0
JP1
Jumper for CAN bus terminator (CAN bus to shaft)
→ Jumper must be set if CBK is located at the end of the CAN bus cable (shaft bus).
JP2
Jumper for CAN bus terminator (CAN bus to HSE)
→ Jumper must be set if CBK is located at the end of the CAN bus cable.
SW1
DIP switches for setting CBK address
DIP4
DIP3
Off
Off
Off
Off
Off
Off
Off
Off
Off
On
Off
On
Off
On
Off
On
On
LED1
LED "Software is running"
LED2
Message transmission on CAN-Bus to HSE
LED3
Message receiving on CAN-Bus to HSE
LED4
Message transmission on CAN-Bus to shaft
LED5
Message receiving on CAN-Bus to shaft
Technical specifications:
Temperature range:
Power supply:
Current consumption:
Mechanical dimensions:
Characteristics and features:
-
Physical segmentation and amplification of CAN bus signal
-
Extension of possible number of bus nodes on shaft bus up to 512
-
PCB in DIN rail housing
-
dsPIC33 microcontroller with internal Flash (64kByte) and RAM (16 kByte)
-
2 integrated CAN-Controller
-
2 CAN bus interfaces with high speed driver according to ISO11898 with galvanic isolation
-
ICSP interface for In-Circuit-Programming (Software download)
DIP2
DIP1
Off
Off
Off
On
On
Off
On
On
Off
Off
Off
On
On
Off
On
On
X
X
X
0°C to +60°C
24V DC
ca. 110mA @ 25°C
Length: 80mm
Width: 70mm
Height: ca. 35mm (without connectors)
CBK1 (Branch 1)
CBK2 (Branch 2)
CBK3 (Branch 3)
CBK4 (Branch 4)
CBK5 (Branch 5)
CBK6 (Branch 6)
CBK7 (Branch 7)
CBK8 (Branch 8)
CBK as Amplifier (e.g. on control bus)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents