Intec MLC 8000 Operating Manual page 168

Lift controller
Table of Contents

Advertisement

INTEC GmbH
Lift controller MLC 8000
22/12/2016
Operating manual V2.0
Position
Terminal no.,
Description
XF10.3
1
NR
2
NL
3
+24A
4
M
5
L
6
0(24V)
7
0(24V)
8
EF17
XF11
1
EAF9
2
EAF10
3
EAF11
4
EAF12
5
EAF13
6
EAF14
7
EAF15
8
EAF16
XF12
1
0(24V)
2
IS
3
TT
4
IU
5
ID
6
IE
7
Frei
8
SKI
9
Frei
10
SKZ
11
Frei
12
SKS
XF13
PE
XF14
1
0(24V)
2
0(24V)
3
0(24V)
4
0(24V)
5
+24V
6
+24V
7
+24V
8
+24A
XF15
1
SKT2
2
3
SKT1
4
5
SKS
6
7
SKN
8
9
SKF
10
XF16
1
N-FK
2
N-FK
Function
Alarm call, e.g. for alarm push on top of car or for alarm horn or external alarm
relay
Emergency light (e.g. in cabin roof); FVE output A7
Battery buffered +24V power supply, e.g. for alarm horn, external alarm relay,
emergency light in cabin roof
Intercom system - microphone (e.g. for additional Intercom unit on top of car
Intercom system - loudspeaker (e.g. for additional Intercom unit on top of car
0V – power supply
Input E17 and Common (0V)
8 Inputs / Outputs E9 to E16 / A9 to A16, free programmable, low active
0V – power supply for inspection inputs
Input E21 (Inspection fast)
Input E22 (2. contact of emergency stop push Inspection)
Input E19 (Inspection upwards)
Input E20 (Inspection downwards)
Input E18 (Inspection on)
Safety circuit (behind Inspection switch)
Safety circuit (behind Inspection switch for door zone bypass)
Safety circuit (before Inspection switch)
Connector for PE (earth) on top of car
0V – power supply
+24V – power supply
Battery buffered +24V – power supply
Safety circuit car door 2
Safety circuit car door 1
Safety circuit, e.g. slack rope switch
Safety circuit, e.g. emergency stop in car operation panel COP
Safety circuit safety gear contact
Note: All safety switches connected here will be bypassed by emergency recall
operation
Neutral car light power supply

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents