1. Menu level
2. Menu level
Set reference
Brake distances
Flush correction
Teach in door
Teach in door 1
Teach in door 2
Teach in door 3
Statistics
Floor count
Maint.count
Clear trip count
Clear op.hours
Clear floorcount
Test
Test runs
Run no.
Lock doors
Disable LC
Out of order
Simulation
3. Menu level
4. Menu level
...
Trips:
Reset counter
73/196
Description
See above "Set reference" by absolute encoder
See above "Brake distances" by incremental encoder
See above "Flush correction" by incremental encoder
Start automatic teach-in run for door controller (only possible by door
controllers according to CANopen lift DSP417)
Check also operating manual of door controller (for example for start
position for teach-in run)
Various statistical values
Displays how often each individual floor has been approached.
Maintenance counter
Number of remaining trips until the expiry of the maintenance interval
Here, the maintenance interval can be restarted.
When monitoring the maintenance interval (see parameter
"Maintenance Interval") this menu item must be started on time before
the expiry of the maintenance interval.
Clearing the trip counter
Note: The trip counter is shown in State display 1.
Clearing the operating time counter
Note: The operating time counter is shown in State display 1.
Clearing the floor counter
Activation of various test modes.
Activation of test runs by the random principle.
The lift can be used normally. If there is no new call after reaching a
floor, the control itself gives a car call randomly.
Number of test runs until the test drive mode is automatically
disabled. By setting '0' the test drive mode must in all cases be
terminated manually.
The lift drives "normal", but does not open the doors (exception:
pressing the door open button in the cabin).
Disable all landing calls
Switch on "Out of order" display, but lift stays in normal mode
Activate lift simulation (e.g. for testing the controller cabinet or for

Hide quick links: