Position
Terminal no.,
Description
3
0(24V)
4
SU
5
0(24V)
6
SM
7
0(24V)
8
SO
9
0(24V)
10
VO
XF7.3
1
CH-
2
CH+
Nur
3
0(24V)
FVE2.1
4
+24V
5
+24A
6
0(24V)
XF8
1.1
2.1
1
1
2
2
3
3
4
4
5
5
6
7
6
8
7
9
8
10
9
11
10
12
XF9
1
SL2
2
SL1
3
Res
4
T2
5
T1
6
T3
7
T2
8
T1
XF10.1
1
0(24V)
2
E1
3
0(24V)
4
E2
5
0(24V)
6
E3
7
0(24V)
8
E4
XF10.2
1
0(24V)
2
E5
3
0(24V)
4
E6
5
0(24V)
6
E7
7
0(24V)
8
E8
Function
Input E25 and 0V (Common) for lower doorzone switch SGU
Input and 0V (Common) for doorzone switch SGM
Onboard connected to trailing cable (XF8.9 - version 1.1; XF8.11 - version 2.1)
Input E24 and 0V (Common) for upper doorzone switch SGO
Input E26 and 0V (Common) for upper prelimit switch VO
Control bus (CAN Bus 1) – Low signal for absolute position encoder
Control bus (CAN Bus 1) – High signal for absolute position encoder
0V – power supply for absolute position encoder
+24V – power supply for absolute position encoder
Battery buffered +24V – power supply for absolute position encoder
0V – power supply for shield CAN bus cable position encoder
Important! Different connector size for FVE version 1.1 and version 2.1
T1
Door motor power 3~ 400V or Door controller power supply 230V (L
+ N) from trailing cable
T2
T3
-
Not used
SL1
Shaft light push to trailing cable
SL2
-
Not used
+24A
Battery buffered +24V power supply from trailing cable
0(24V)
0V – power supply input from trailing cable
+24V
+24V power supply from trailing cable
SM
Door zone switch SGM to trailing cable
NR
Alarm call to trailing cable
Shaft light push on top of car
Free connector, onboard connected to XF17.9
230V-N for 2. door controller (connected to XF9.2)
230V-L for 2. door controller (connected to XF9.1)
Door motor 400V-L3
Door motor 400V-L2 or 230V-N (Door controller)
Door motor 400V-L1 or 230V-L (Door controller)
Input E1 and Common (0V), low side switching, free programmable, for door
open switch door 1
Input E2 and Common (0V), low side switching, free programmable, for door
closed switch door 1
Input E3 and Common (0V), low side switching, free programmable, for door
reverse switch door 1 (mechanical obstacle)
Input E4 and Common (0V), low side switching, free programmable, for light
screen door 1
Input E5 and Common (0V), low side switching, free programmable, for door
open switch door 2
Input E6 and Common (0V), low side switching, free programmable, for door
closed switch door 2
Input E7 and Common (0V), low side switching, free programmable, for door
reverse switch door 2 (mechanical obstacle)
Input E8 and Common (0V), low side switching, free programmable, for light
screen door 2