Source:modulation Subsystem; Source:pgen Subsystem - R&S SMB100A Operating Manual

Rf and microwave signal generator
Hide thumbs Also See for SMB100A:
Table of Contents

Advertisement

®
R&S
SMB100A
Parameters:
<Source>
Example:
Manual operation:

7.13.8 SOURce:MODulation Subsystem

This subsystem contains the command for switching on/off all modulations.
[:SOURce<hw>]:MODulation[:ALL][:STATe] <State>
Activates/deactivates the modulations.
The command SOUR:MOD:ALL:STAT OFF switches all modulations off. A subsequent
command SOUR:MOD:ALL:STAT ON restores the status that was active before the
last switch-off. "MOD OFF" is displayed in the info line of the header next to the "Level"
field.
Parameters:
<State>
Example:
Manual operation:

7.13.9 SOURce:PGEN Subsystem

This subsystem contains the commands for setting the pulse generator.
[:SOURce<hw>]:PGENerator:STATe
Operating Manual 1407.0806.32 ─ 21
AUTO | IMMediate | SINGle | BUS | EXTernal
AUTO|IMMediate
The trigger is free-running, i.e. the trigger condition is fulfilled
continuously. The selected list in List mode is restarted as soon
as it is finished.
SINGle|BUS
The list is triggered by the GPIB commands
LIST:TRIGger:EXECute. The list is executed once.
EXTernal
The list is triggered externally via the INST TRIG connector. The
list is executed once.
*RST:
AUTO
LIST:TRIG:SOUR EXT
selects triggering by means of the external trigger.
See
"Mode - List Mode"
0 | 1 | OFF | ON
*RST:
1
MOD:STAT OFF
switches off all modulations.
See
"MOD ON/OFF"
on page 197
............................................................................... 372
Remote Control Commands
SOURce Subsystem
[:SOURce<hw>]: