Example:
Usage:
Options:
[:SOURce<hw>]:PULM:TRAin:ONTime <OnTime>
Fills the On-time part of the selected file with data.
Parameters:
<OnTime>
Example:
Options:
Manual operation:
[:SOURce<hw>]:PULM:TRAin:ONTime:POINts?
Queries the length (in points) of the ontime component of the selected list.
Return values:
<Points>
Operating Manual 1407.0806.32 ─ 21
MMEM:CDIR '/var/user/Lists'
selects the directory for the pulse train files.
PULM:TRA:SEL 'P_INCR'
selects P_INCR for editing. P_INCR is created if it does not yet
exist.
PULM:TRA:OFFT:POIN?
queries the number of frequency values in P_INCR
Response: 7
P_INCR has 7 off-time entries.
Query only
R&S SMB-K27 (Pulse Train)
Ontime#1{, Ontime#2, ...} | binary block data
The data can be given either as a list of numbers (list can be of
any length and list entries must be separated by commas) or as
binary block data.
When block data is transferred, 8 (4) bytes are always interpre-
ted as a floating-point number with double accuracy (see the
command FORMat:DATA).
The maximum length is 2047 values.
MMEM:CDIR '/var/user/Lists'
selects the directory for the pulse train files.
PULM:TRA:SEL 'P_INCR'
selects P_INCR for editing. P_INCR is created if it does not yet
exist.
PULM:TRA:ONT 10ns,30ns,40ns,...
specifies the on-time values in P_INCR. If the list already con-
tains data, it is overwritten.
R&S SMB-K27 (Pulse Train)
See
"Edit Pulse Train Data"
integer
Range:
0 to 2047
*RST:
0