R&S SMB100A Operating Manual page 478

Rf and microwave signal generator
Hide thumbs Also See for SMB100A:
Table of Contents

Advertisement

®
R&S
SMB100A
Example:
Example:
STEReo:DIRect "EON-DEL=<PI>"
Enhanced Other Networks: deletes the complete EON with selected <PI>.
Parameters:
<PI>
Example:
Usage:
STEReo:DIRect "EON-PI=<PI>"
STEReo:DIRect? "EON-PI"
Enhanced Other Networks: creates a new EON or reads the list of the program identifi-
cation (PI) codes of all EONs created so far.
Note: A maximum of eight EONs can be created.
Parameters:
<PI>
Example:
Example:
STEReo:DIRect "EON-PS=<PI>,<PS>"
STEReo:DIRect? "EON-PS,<PI>"
Enhanced Other Networks: sets the program service (PS) name for the EON with the
selected <PI>.
Parameters:
<PI>
Operating Manual 1407.0806.32 ─ 21
Direct Commands for the Stereo/RDS Coder Option R&S SMB-B5
STEReo:DIRect "EON-AFB=1000,N,97.4,98.3"
Creates a new type B alternative frequency list for the EON with
PI=1000.
The list contains the alternative frequencies 97.4 MHz and 98.3
MHz.
STEReo:DIRect? "EON-AFB,1000,1"
Reads the first type B alternative frequency list of the EON with
PI=1000.
Response: "97.4,98.3"
Range:
0000 to FFFF (ASCII coded hexadecimal num-
bers)
STEReo:DIRect "EON-DEL=1000"
Deletes the EON with PI=1000.
Setting only
Note: A four-digit value must always be set. Leading zeros, if
any, must also be specified.
Range:
0000 to FFFF (ASCII coded hexadecimal num-
bers)
STEReo:DIRect "EON-PI=1000"
Creates a new EON with PI=1000.
STEReo:DIRect? "EON-PI"
Response: "1000"
Range:
0000 to FFFF (ASCII coded hexadecimal num-
bers)
Remote Control Commands
463

Advertisement

Table of Contents
loading

Table of Contents