[:SOURce<hw>]:CORRection:CSET:DATA:POWer:POINts?
Queries the number of level values in the selected table.
The numerical suffix at SOURce must not be used for this command.
Return values:
<Points>
Example:
Usage:
[:SOURce<hw>]:CORRection:CSET:DATA[:SENSor<ch>][:POWer]:SONCe
The command fills the selected user correction list with the level values measured by
the power sensor for the given frequencies.
To select the used power sensor set the suffix in key word SENSe.
Example:
Usage:
Manual operation:
[:SOURce]:CORRection:CSET:DELete <Filename>
Deletes the specified table.
The lists are stored with the fixed file extensions *.uco in a directory of the user's
choice. The directory applicable to the commands is defined with the command
MMEMory:CDIR. A path can also be specified in command SOUR:CORR:CSET:CAT?,
in which case the file in the specified directory is deleted.
Setting parameters:
<Filename>
Example:
Usage:
Manual operation:
Operating Manual 1407.0806.32 ─ 21
integer
Range:
0 to 10000
*RST:
0
CORR:CSET '/var/user/ucor1'
selects the table ucor1.
CORR:CSET:DATA:POW:POIN?
queries the number of level values in the table ucor1.
Response: 440
the table ucor1 contains 440 level values.
Query only
CORR:CSET:DATA:SENS:POW:SONC
fills the user correction list with level values acquired by the
power sensor connector to the SENSOR connector.
Event
See
"Fill User Correction Data with Sensor"
<table name>
MMEM:CDIR '/var/user/ucor'
selects the directory for the user correction files.
CORR:CSET:DEL 'UCOR1'
deletes the table ucor1.
Setting only
See
"User Cor. Data - User Correction"
Remote Control Commands
SOURce Subsystem
on page 165
on page 159