Remote command:
[:SOURce<hw>]:SWEep[:FREQuency]:SHAPe
Retrace - RF Frequency Sweep
Activates that the signal changes to the start frequency value while it is waiting for the
next trigger event.
You can enable this feature, when you are working with sawtooth shapes in sweep
mode "Single" or "External Single", see
Remote command:
[:SOURce<hw>]:SWEep[:FREQuency]:RETRace
Step Lin/Log - Frequency Sweep
Sets the step width for the individual frequency sweep steps.
At each step this value is added to the current frequency.
Depending on the
parameter is displayed.
"Step Lin"
Remote command:
[:SOURce<hw>]:SWEep[:FREQuency]:STEP[:LINear]
Operating Manual 1407.0806.32 ─ 21
Spacing - Frequency Sweep
The step width is a constant value in Hz.
on page 422
Mode - RF Frequency
on page 422
mode you have set, the corresponding
on page 423
Instrument Function
RF Block
Sweep.
180