R&S SMB100A Operating Manual page 206

Rf and microwave signal generator
Hide thumbs Also See for SMB100A:
Table of Contents

Advertisement

®
R&S
SMB100A
The "Dwell Time" set by the user is used as the step time of the list mode. The effec-
tive net dwell time is shorter, reduced by the setting time. This setting time may be
greater than the time specified in the data sheet.
Remote command:
[:SOURce<hw>]:LIST:DWELl
Current Index - List Mode
Sets the list index in "Step" mode.
Remote command:
[:SOURce<hw>]:LIST:INDex
Learn List Mode Data... - List Mode
Starts the determination of the hardware setting for the selected list. The data deter-
mined in this way is stored along with the list.
It may be necessary to deliberately activate list learning in the event of greatly altered
environmental conditions that require new hardware settings.
If this is not done, a previously learned hardware setting will continue to be used when
list mode is switched on ("State = On"). If no setting is available, e.g. when the list is
used for the first time, learning is automatically activated.
Remote command:
[:SOURce<hw>]:LIST:LEARn
List Mode Data... - List Mode
Calls the "File Select" menu for selecting and creating a list or the "File Manager".
Remote command:
[:SOURce<hw>]:LIST:SELect
[:SOURce<hw>]:LIST:DELete
[:SOURce<hw>]:LIST:DELete:ALL
Operating Manual 1407.0806.32 ─ 21
on page 365
on page 366
on page 368
on page 370
on page 360
on page 361
Instrument Function
RF Block
191