Setting parameters:
<A>
Query parameters:
<z>
Example:
Example:
STEReo:DIRect "EON-AFB= <PI>,<A>,<Freq#1>,<Freq#2>,..."
STEReo:DIRect? "EON-AFB,<PI>,<z>"
Enhanced Other Networks: defines type B alternative frequencies for the EON with the
selected PI.
Parameters:
<PI>
<Freq>
Setting parameters:
<A>
Query parameters:
<z>
Operating Manual 1407.0806.32 ─ 21
Direct Commands for the Stereo/RDS Coder Option R&S SMB-B5
N
new AF list
+
AF list to be added
AF list to be read
Range:
1 to 5
STEReo:DIRect "EON-AFA=1000,N,97.4,98.3"
Creates a new type A alternative frequency list for the EON with
PI=1000.
The new list contains the alternative frequencies 97.4 MHz and
98.3 MHz.
STEReo:DIRect? "EON-AFA,1000,1"
Reads the first type A alternative frequency list of the EON with
PI=1000.
Response: "97.4,98.3"
Range:
0000 to FFFF (ASCII coded hexadecimal num-
bers)
xxx.x
Sets the alternative frequencies as ASCII coded decimal num-
bers.
If list <z> is not available, the response is ().
Note: For each Enhanced Other Network (EON), a maximum of
five type B alternative frequency lists can be created, each list
containing max. five frequencies, where <Freq#1> is Tuned Fre-
quency (TF) and <Freq#2..5> are the Mapped Frequencies
(MF). A minimum of two frequencies per EON is required.
Range:
87.6 to 107.9
N
new AF list
+
AF list to be added
AF list to be read
Range:
1 to 5