Sign In
Upload
Manuals
Brands
R&S Manuals
Inverter
SMA100B
R&S SMA100B Manuals
Manuals and User Guides for R&S SMA100B. We have
3
R&S SMA100B manuals available for free PDF download: User Manual, Getting Started
R&S SMA100B User Manual (822 pages)
RF Signal Generator
Brand:
R&S
| Category:
Portable Generator
| Size: 29 MB
Table of Contents
Table of Contents
3
Safety and Regulatory Information
19
Safety Instructions
19
Labels on R&S SMA100B
21
Warning Messages in the Documentation
22
Korea Certification Class a
22
Welcome
23
Key Features
23
What's New
23
Documentation Overview
23
Getting Started Manual
24
User Manuals and Help
24
Service Manual
24
Instrument Security Procedures
24
Printed Safety Instructions
24
Data Sheets and Brochures
24
Release Notes and Open Source Acknowledgment (OSA)
25
Application Notes, Application Cards, White Papers, Etc
25
Getting Started
26
Preparing for Use
26
Lifting and Carrying
26
Unpacking and Checking
26
Choosing the Operating Site
26
Setting up the R&S SMA100B
27
Placing the R&S SMA100B on a Bench Top
27
Mounting the R&S SMA100B in a Rack
28
Considerations for Test Setup
29
Connecting to Power
30
Connecting to LAN
30
Connecting USB Devices
31
Connecting to RF
32
Connecting to Ref In/Ref out
33
Switching on or off
34
Instrument Tour
35
Front Panel Tour
36
Touchscreen
37
Utility Keys
38
On/Standby
38
Function Keys
38
Keypad
38
Navigation Controls
39
Rotary Knob
39
Editing Keys
39
Navigation Keys
40
Display Keys
40
SD Card Slot
40
USB Connector
40
Sensor
41
Rf 50 Ω
41
Clock Synthesizer Connectors
42
LF Modulation Connectors
42
Pulse Signal Connectors
42
Rear Panel Tour
43
Connectors
44
Trying out the Instrument
46
Generating an Unmodulated Carrier
46
Generating an RF Frequency Sweep Signal
49
Saving and Recalling Settings
51
Instrument Control
53
Means of Manual Interaction
54
Possible Ways to Operate the Instrument
54
Understanding the Display Information
55
Status Bar
56
Taskbar
56
Tile Diagram
56
Additional Display Characteristics
57
Accessing the Functionality
58
Entering Data
59
Entering Alphanumeric Parameters
60
Entering Numeric Parameters
60
Undo and Redo Actions
60
Getting Information and Help
61
Remote Control
62
Remote Operation over VNC
63
RF Signal Configuration
64
Activating RF Signal Output
65
How to Set the Frequency and Level
65
How to Generate a Phase Continuous RF Signal
67
Phase Continuous Frequency
67
RF Connector Settings
68
RF Frequency Settings
71
RF Level Settings
74
Settings
75
Amplitude
75
RF State/Rf on
75
Limit
76
Offset
76
Setting Characteristics
76
Harmonic Filter
77
Level Range
77
Readjust
78
RF Phase Settings
78
User Variation
78
Analog Modulations
81
Modulation Types and Signal Sources
81
Required Options
81
Activating Analog Modulations
84
Modulation Settings
84
Pulse Modulation Settings
84
FM, Phim and am Modulation Settings
86
Analog Modulations
87
Source
87
Source State
87
Deviation
88
Deviation Mode
88
FM Settings
88
Ratio Path2/Path1
88
Total Deviation
88
Deviation
89
Deviation Mode
89
Mode
89
Phim Settings
89
AM Settings
90
Mode
90
Ratio Path2/Path1
90
Total Deviation
90
Mode
91
Type
91
Depth
92
Deviation Mode
92
Sensitivity
92
Total Depth
92
Chirp Modulation
93
Ratio Path2/Path1
93
Chirp Modulation Settings
94
Chirp Modulation
95
Pulse External / Trigger
97
Pulse Generator
98
Pulse Generator > General Settings
99
Pulse Generator > Pulse Train Settings
104
Import/Export List Files
108
Pulse Graph
111
Pulse External / Trigger Settings
112
FM, Phim and am Modulation Sources
113
Source > LF Generator Settings
113
Analog Modulations
114
Shape
114
State (LF Frequency Sweep)
114
Frequency
116
Period
116
Pulse Duty Cycle
116
Pulse Width
116
Source > External Settings
117
Trapezoid High
117
Trapezoid Rise / Fall
117
Triangle Rise
117
Source > Noise Generator Settings
119
LF Signal Output Settings
120
Overview
122
How to Generate a Pulse Modulated Signal
124
How to Generate an Amplitude Modulated Signal
124
How to Generate a Pulse Train Modulated Signal
125
Avionic Standards
127
About the Avionics Options
127
Required Options
127
Required Options
128
VHF Omni Directional Radio Range (VOR)
128
Instrument Landing System (ILS)
129
Automatic Direction Finder (ADF)
133
VOR Configuration and Settings
133
General Settings
134
Signal Settings
137
Position Settings
139
COM/ID Settings
140
General Settings
142
ILS Configuration and Settings
142
General Settings
145
ILS Glide Slope Settings
145
Signal Settings
147
Amplitude Settings
149
ILS Localizer Settings
151
General Settings
152
Signal Settings
154
Amplitude Settings
155
COM/ID Settings
158
ILS Marker Beacons Settings
160
General Settings
161
Signal Settings
162
COM/ID Settings
163
ADF Configuration and Settings
165
General Settings
166
COM/ID Settings
168
List and Sweep Mode
171
Signal Generation and Triggering in the Sweep and List Modes
173
About Sweep Mode
180
Correlating Parameters in Sweep Mode
181
Sweep Signal Shapes
183
About List Mode
184
Significant Parameters and Functions
185
General Sweep Settings
187
Sweep Mode Settings
187
Settings Sweep Type/State (Rf Frequency Sweep)
188
Settings Sweep Type
188
State (RF Frequency Sweep)
188
Current Frequency
189
Current Level
189
Mode
189
State (LF Frequency Sweep)
189
State (RF Frequency / Level Sweep)
189
State (RF Level Sweep)
189
Retrace
190
Shape
191
Dwell Time
192
Spacing
192
Sweep Time
192
Execute Single Sweep
193
Reset Sweep
193
Show Connector
193
Trigger Slope
193
Frequency Range Settings
194
Level Range Settings
196
Output Settings
198
Edit Marker Settings
199
List Mode Settings
201
General Settings
202
List Mode Data Settings
204
Import/Export Settings
205
List Editor
207
How to Generate a Signal in List or Sweep Mode
211
Attenuator
213
Improving Level Performance
213
Attenuator Settings
214
Automatic Level Control (ALC)
216
Reverse Power Protection
216
ALC Settings
218
How to Set up an External ALC
220
User Correction
221
User Correction Settings
223
List Editor
225
Fill with Sensor
229
Import/Export List Files
230
Connecting R&S NRP Power Sensors to the R&S SMA100B
233
Using Power Sensors
233
NRP Sensor Mapping
234
About
237
NRP Power Viewer
237
NRP Power Viewer Settings
239
Table of Contents
241
Display
242
Frequency
242
Level Offset State,Level Offset
242
Permanent
242
Use Frequency of
242
Filter
243
Filter Length
243
Noise/Signal Ratio
243
Aperture Time
244
Enable Logging
244
Time
244
Timeout
244
About
245
NRP-Z Power Analysis
245
Required Options
245
Accessing the NRP-Z Power Analysis Functionality
247
NRP-Z Traces/Markers Settings
249
Test Setup Example
249
Trace Settings
251
Define Reference NRP-Z Analysis Settings
252
Marker Settings
254
Configure Measurement Settings
255
NRP-Z Configure Settings
255
Configure Sensors Settings
259
Configure Diagram
263
Configure Time Mode Settings
264
Trace Settings
265
Pulse Data Notifications Settings
267
Trigger Settings
272
Gate Mode Settings
274
Next Window List
276
Creating Screenshots of Power Analysis Settings
280
Save (Power Analysis) Settings
280
How to Save a Hardcopy of the Power Analysis Window
285
How to Set up a Frequency Sweep Measurement
287
How to Set up a Power Sweep Measurement
288
How to Set up a Pulse Measurement
288
How to Configure the Power Analysis Diagram
289
How to Calibrate the Power Level with an R&S NRP Power Sensor
290
Reference Frequency Settings
294
Reference Oscillator
294
Required Options
294
[:Source]:Roscillator:preset Source
296
Deactivate RF Output (if External Reference Is Missing)
296
External Reference Frequency
296
Frequency
297
Minimum Locking Range
297
Nominal Synchronization Bandwidth
297
Synchronization Bandwidth
297
External Tuning Active
298
External Tuning Slope
298
Reference Output Settings
298
Adjustment Settings
299
Using the Reference Frequency for Instruments Synchronization
300
Clock Synthesis
304
File and Data Management
308
About the File System
308
Restoring the (Default) Instrument Configuration
311
Preset, Set to Default and Factory Preset Settings
313
How to Identify Parameters Which Are Not in a Preset State
314
How to Recall User Settings Automatically after Preset
315
Reference
315
Protecting Data
316
Saving and Recalling Instrument Settings
317
Save/Recall Settings
318
How to Save and Recall Instrument Settings
320
Accessing Files with User Data
321
File Select Settings
321
Exporting and Importing Remote Command Lists
323
Loading, Importing and Exporting Lists
324
Using the File Manager
324
File Manager Settings
325
Map Network Share Settings
326
How to Display All Saved Files
328
How to Map a Network Folder
328
How to Transfer Files from and to the Instrument
330
Removing File System Protection
331
Accessing the File System of the R&S SMA100B Via FTP
332
Accessing the R&S SMA100B File System Via SMB (Samba)
333
Using a File Server for Test Files Exchange
335
Using a USB Storage Device for File Transfer
335
Creating Screenshots of Current Settings
336
Hardcopy Settings
336
How to Save a Hardcopy of the Display
340
Customizing the User Interface
342
General Instrument Functions
342
Display and Keyboard Settings
343
Display Update Settings
344
Defining the RF Signal State on Power on
345
How to Set the Initial Instrument Settings
346
Setting the Keyboard Language
346
Setting the Screen Saver
346
Organizing Frequently Used Settings as Favorites
347
User Menu Settings
348
How to Use the User Menu for Fast Adjustments
349
Define User Key Actions Settings
351
How to Assign Actions to the [★ (User)] Key
353
Manage License Keys Settings
354
Managing Licenses and License Keys
354
Using the License Server
357
How to Move a Portable License
359
Using the Security Settings
360
Protection Level Settings
362
Setting Security Parameters
363
Update Policy Security Settings
363
Disk & Memory Security Settings
364
Manual Operation Security Settings
366
Configuring LAN Services
368
Password Management
370
How to Prevent Unauthorized Access
373
Undoing or Restoring Actions
376
Shutting down and Rebooting the Instrument
377
Network Operation and Remote Control
378
Overview of Remote Access Modes
379
Remote Control Interfaces and Protocols
380
LAN Interface
381
VISA Resource Strings
381
USB Interface
383
USB Resource String
383
GPIB Interface (IEC/IEEE Bus Interface)
384
RS232 Resource String
384
LXI Browser Interface
385
Remote Control Programs and Libraries
385
Hierarchy of the Status Registers
388
Status Reporting System
388
Structure of a SCPI Status Register
390
Status Byte (STB) and Service Request Enable Register (SRE)
392
Event Status Register (ESR) and Event Status Enable Register (ESE)
393
Questionable Status Register (Status:questionable)
393
Application of the Status Reporting System
394
Operation Status Register (Status:operation)
394
Service Request
394
Error Queue
395
Query of an Instrument Status
395
Serial Poll
395
Remote Access Settings
396
Reset Values of the Status Reporting System
396
Network Settings
397
VISA Resource Strings
400
GPIB Address Settings
402
RS232 Settings
402
Instrument Emulations Settings
403
Active Connections
405
Remote Connections Settings
405
Closed Connections
406
QR Code
406
LXI Settings
407
LXI Status Settings
407
LXI Browser Settings
409
IP Configuration
410
LAN Configuration
410
Advanced Config
411
Ping Client
412
SCPI Remote Trace
412
Connecting the Instrument to the Network (LAN)
414
Datasheet
414
How to Activate LAN Services
415
How to Connect to LAN
415
How to Enable Access Via LAN
415
How to Assign the IP Address
416
Controlling the R&S SMA100B Remotely
417
How to Use Computer Names (Hostnames)
417
How to Find the VISA Resource String
418
How to Change the GPIB Instrument Address
419
Establishing a Remote Control Connection over LAN Using VXI-11 Protocol
420
Establishing a Remote Control Connection over the LXI Browser Interface
420
Establishing a Remote Control Connection over LAN Using Socket Communication
425
Setting up a Remote Control Connection over GPIB
426
Setting up a Remote Control Connection over USB
427
How to Return to Manual Operation
428
How to Trace Messages with the LXI Web Browser Interface
428
Automating Tasks with Remote Command Scripts
429
Displaying an SCPI List
432
Show SCPI Command
432
SCPI Recording Export Settings
433
How to Record / Create SCPI Lists
434
How to Convert and Save SCPI Lists
437
How to Find out the SCPI Commands for GUI Functions
438
How to Enable the VNC Service
439
Operating the R&S SMA100B Remotely Using VNC
439
How to Set up Remote Operation from a Desktop System
440
Using a VNC Client Software
440
Using a Web Browser
440
How to Set up Remote Operation from a Smart Device
442
Using a VNC App
443
Using a Web Browser with HTML5
443
Special Mode QR Code
444
Code Generator Templates
445
LXI Functionality
445
References
445
Remote Control States
447
Conventions Used in SCPI Command Descriptions
449
Remote Control Commands
449
Common Commands
450
Programming Examples
450
Preset Commands
455
Mmemory Subsystem
456
File Naming Conventions
457
Accessing Files in the Default or in a Specified Directory
458
Programming Examples
459
Remote Control Commands
461
Calibration Subsystem
467
Csynthesis Subsystem
469
Diagnostic Subsystem
474
Display Subsystem
477
Format Subsystem
482
Hcopy Subsystem
483
Hard Copy Settings
484
Automatic Naming
486
Kboard Subsystem
488
Output Subsystem
489
Power Sensor Measurement Subsystems
493
Calculate Subsystem
494
Display Subsystem
501
Initiate Command
501
Sense Sweep Subsystem
502
Trace Subsystem
534
Sense, READ, Initiate and Slist Subsystems
546
Source Subsystem
560
Analog Modulation Subsystems
561
Source:modulation Subsystem
561
Source:am Subsystem
562
Source:chirp Subsystem
568
Source:fm Subsystem
572
Source:pm Subsystem
577
Pulse Modulation Settings
581
Source:pulm Subsystem
581
Pulse Train Settings
587
Pulse Train Data Exchange
589
Avionic Standards Subsystems
592
Advertisement
R&S SMA100B User Manual (581 pages)
RF signal generator
Brand:
R&S
| Category:
Inverter
| Size: 8 MB
Table of Contents
Table of Contents
18
Customer Support
17
1 Preface
30
For Your Safety
30
Key Features
30
About this Manual
31
Documentation Overview
32
Getting Started Manual
32
Service Manual
32
User Manuals and Help
32
Application Notes, Application Cards, White Papers, Etc
33
2 Getting Started
34
Basic Safety Instructions
33
Data Sheets and Brochures
33
Instrument Security Procedures
33
Release Notes and Open Source Acknowledgment (OSA)
33
Preparing for Use
34
Putting into Operation
34
EMI Suppression
35
Unpacking and Checking the Instrument
35
Accessory List
36
Placing or Mounting the Instrument
36
Connecting AC Power
37
Turning the Instrument on and off
38
Functional Check
39
Checking the Supplied Options and Licenses
40
Connecting USB Devices
40
Setting up a Network (LAN) Connection
41
Connecting the Instrument to the Network
41
Using Computer Names (Hostnames)
42
Assigning the IP Address
43
Configuring the Initial Instrument Settings
44
Setting the Date and Time
45
Setting the Keyboard Language
46
Setting the Screen Saver
46
Front Panel Tour
47
Instrument Tour
47
Touchscreen
49
Utility Keys
49
Function Keys
50
Keypad
50
On/Standby
50
Editing Keys
51
Navigation Controls
51
Rotary Knob
51
Display Keys
52
Navigation Keys
52
USB Connector
52
SD Card Slot
53
Rf 50 Ω
53
Sensor
53
LF Modulation Connectors
54
Pulse Signal Connectors
54
Clock Synthesizer Connectors
55
Rear Panel Tour
55
Connectors
56
Trying out the Instrument
58
Generating an Unmodulated Carrier
59
Generating an RF Frequency Sweep Signal
61
Saving and Recalling Settings
63
Instrument Control
66
2.4.1 Possible Ways to Operate the Instrument
67
Means of Manual Interaction
67
Possible Ways to Operate the Instrument
67
Status Bar
68
Tile Diagram
68
Understanding the Display Information
68
Taskbar
69
Additional Display Characteristics
70
Accessing the Functionality
71
Entering Data
72
Entering Alphanumeric Parameters
73
Entering Numeric Parameters
73
Undo and Redo Actions
73
Getting Information and Help
74
Remote Control
75
Remote Operation over VNC
76
Vnc
76
3 RF Signal Configuration
77
Activating RF Signal Output
78
How to Set the Frequency and Level
78
RF Frequency Settings
80
RF Level Settings
82
Output
84
Amplitude
84
RF State/Rf on
84
Limit
85
Offset
85
Setting Characteristics
85
Harmonic Filter
86
Level Range
86
RF Phase Settings
87
Mode
86
Readjust
87
User Variation
87
4 Analog Modulations
89
Modulation Types and Signal Sources
89
Required Options
89
Activating Analog Modulations
91
Modulation Settings
91
Pulse Modulation
92
FM, Phim and FM Modulation Settings
93
Source State
94
FM Settings
95
Deviation
95
Ratio Path2/Path1
95
Mode
96
Source
95
Phim
96
Deviation
96
Ratio Path2/Path1
96
AM Settings
97
AM Depth
97
Ratio Path2/Path1
97
Pulse Generator
97
Pulse Generator > General Settings
98
Pulse Generator > Pulse Train Settings
102
Import/Export List Files
106
Settings Mode/Ascii File Settings
107
ASCII File Settings
107
Settings Mode
107
Select Source / Select ASCII Destination
108
Select Source/Select Destination
108
Import / Export
109
Pulse Graph
109
Pulse External/Trigger Settings
110
FM, am and Phim Modulation Sources
111
Source > LF Generator Settings
111
Source > External Settings
115
Source > Noise Generator Settings
116
LF Signal Output Settings
117
Overview
119
How to Generate an Amplitude Modulated Signal
120
How to Generate a Pulse Modulated Signal
121
How to Generate a Pulse Train Modulated Signal
122
References
123
Simultaneous Operation of Several Modulations
123
Correlating Parameters in Sweep Mode
133
About List Mode
135
Significant Parameters and Functions
136
General Sweep Settings
138
Sweep Mode Settings
138
Frequency Range Settings
143
Level Range Settings
145
List Mode Settings
146
General Settings
147
List Mode Data Settings
149
Import/Export Settings
150
List Editor
153
How to Generate a Signal in List or Sweep Mode
155
Attenuator
158
Attenuator Settings
159
Reverse Power Protection
160
ALC - Automatic Level Control
161
ALC Settings
162
User Correction
163
User Correction Settings
164
List Editor
166
Fill with Sensor
169
Import/Export List Files
170
Connecting R&S NRP Power Sensors to the R&S SMA100B
173
Using Power Sensors
173
NRP Sensor Mapping
174
NRP Power Viewer
176
5 Varying the RF Signal in List or Sweep Mode
124
Signal Generation and Triggering in the Sweep and List Modes
125
About Sweep Mode
133
About
176
NRP Power Viewer Settings
178
NRP Info Update
183
How to Update the Sensor Firmware
185
How to Calibrate the Power Level with an R&S NRP Power Sensor
186
Required Options
190
Using the Reference Frequency for Instruments Synchronization
190
Reference Frequency Settings
193
Reference Output Settings
197
Adjustments Settings
198
6 Improving Level Performance
158
7 Reference Oscillator
190
8 Clock Synthesis
199
9 File and Data Management
203
About the File System
203
System
203
Accessing Files with User
204
Exporting Remote Command
204
Loading, Importing and Exporting
204
Manager
204
Restoring the (Default) Instrument Configuration
206
Configuration
206
Preset, Set to Default and Factory Preset Settings
208
How to Identify Parameters Which Are Not in a Preset State
209
How to Recall User Settings Automatically after Preset
209
Reference
210
Protecting Data
211
Data
211
Saving and Recalling Instrument Settings
212
Save/Recall Settings
212
Settings
212
How to Save and Recall Instrument Settings
215
Accessing Files with User Data
216
Data
216
Exporting Remote Command Lists
218
Lists
218
Lists
219
Loading, Importing and Exporting Lists
219
Using the File Manager
219
File Manager Settings
220
How to Display All Saved Files
221
How to Transfer Files from and to the Instrument
222
Removing File System Protection
222
File Select Settings
216
Instrument
222
Accessing the File System of the R&S SMA100B Via Ftp
223
Accessing the R&S SMA100B File System Via SMB (Samba)
225
Using a USB Storage Device for File Transfer
226
Creating Screenshots of Current Settings
227
Hard Copy Settings
227
Settings
227
How to Store a Hardcopy of the Display
231
10 General Instrument Functions
233
Customizing the User Interface
233
Display and Keyboard Settings
234
Display Update Settings
235
Defining the RF Signal State on Power on
236
Organizing Frequently Used Items as Favorites
237
Using the User Menu for Fast Adjustments
238
Define User Key Actions Settings
240
Assigning Actions to the User Key
241
Managing Licenses and License Keys
243
Manage License Keys Settings
243
How to Move a Portable License
245
Managing the Security Settings
247
Protection Level Settings
248
Setting Security Parameters
249
Configuring LAN Services
253
Password Management
254
Undoing or Restoring Actions
257
Shutting down and Rebooting the Instrument
258
11 Network Operation and Remote Control
259
Overview of Remote Access Modes
259
Remote Control Interfaces and Protocols
261
LAN Interface
262
VISA Resource Strings
262
Hislip Protocol
264
Protocol
264
Socket Communication
264
USB Interface
265
USB Resource String
265
GPIB Interface (IEC/IEEE Bus Interface)
265
LXI Browser Interface
266
Remote Control Programs and Libraries
267
VISA Library
267
Possible Setups and Access Functions
268
Remote Access Settings
270
Network Settings
271
VISA Resource Strings
274
GPIB Address Settings
275
RS232 Settings
275
Instrument Emulations Settings
276
Active Connections Settings
278
QR Code
279
LXI Settings
280
LXI Status Settings
280
LXI Browser Settings
281
LAN Configuration
282
IP Configuration
282
Advanced Config
283
Ping Client
284
SCPI Remote Trace
285
Data Sheet
286
How to Find the VISA Resource String
287
How to Change the GPIB Instrument Address
288
How to Set up a Remote Control Connection
288
Establishing a Remote Control Connection over the LXI Browser Interface
289
Establishing a Remote Control Connection over LAN Using VXI-11 Protocol
290
Setting up a Remote Control Connection over LAN Using Socket Communication
295
Setting up a Remote Control Connection over GPIB
296
Setting up a Remote Control Connection over USB
297
How to Return to Manual Operation
298
Tracing SCPI Commands and Messages Exchanged Via the LXI Web Browser Interface
298
Automating Tasks with Remote Command Scripts
299
Displaying an SCPI List
302
Show SCPI Command
302
SCPI Recording Export Settings
303
How to Find out the SCPI Command Corresponding to the Manual Operation Using the Online Help
305
How to Find out the SCPI Command Corresponding to the Manual Operation Via "Show SCPI Command
305
How to Record / Create SCPI Lists
306
How to Convert and Save SCPI Lists
309
How to Set up Remote Operation Via VNC
310
Setting up a Remote Operation from a Desktop System
310
Using a Web Browser
310
Using a VNC Client Software
311
Setting up a Remote Operation from a Smart Device
313
Using a VNC App
314
Using a Web Browser with HTML5
314
Special Mode QR Code
315
Code Generator Templates
316
LXI Functionality
316
References
316
Remote Control States
318
12 Remote Control Commands
320
Conventions Used in SCPI Command Descriptions
320
Common Commands
321
Programming Examples
321
Preset Commands
326
Mmemory Subsystem
327
File Naming Conventions
328
Accessing Files in the Default or in a Specified Directory
329
Programming Examples
330
Remote Control Commands
332
Calibration Subsystem
337
Table of Contents
338
Calibration:level:bwidth
339
Calibration:lfoutput[:Measure]
340
Calibration<Hw>:All:date
340
Calibration<Hw>:All:temp
340
Calibration<Hw>:Debug
340
Calibration<Hw>:Fmoffset[:Measure]
341
Calibration<Hw>:Frequency[:Measure]
341
Calibration<Hw>:Level:extern:data
341
Calibration<Hw>:Level:extern:exec
342
Calibration<Hw>:Level:state
342
Calibration<Hw>:Level[:Measure]
342
Csynthesis Subsystem
343
Diagnostic Subsystem
348
Display Subsystem
350
Format Subsystem
355
Hcopy Subsystem
356
Programming Examples
357
Hard Copy Settings
358
Automatic Naming
359
12.12 Kboard Subsystem
362
Kboard Subsystem
362
Output Subsystem
362
Output<Hw>:Amode
363
Output<Hw>[:State]
363
Output<Hw>[:State]:Pon
363
Output<Hw>:Afixed:range:lower
364
Output<Hw>:Afixed:range:upper
364
Output<Hw>:Impedance
364
Output<Hw>:Filter:mode
365
Sense, READ, Initiate and Slist Subsystems
366
Output<Hw>:Protection:clear
365
Output<Hw>:Protection:tripped
365
R&S SMA100B Getting Started (59 pages)
RF Signal Generator
Brand:
R&S
| Category:
Portable Generator
| Size: 4 MB
Table of Contents
Table of Contents
2
Safety Information
5
Key Features
6
Documentation Overview
7
Getting Started Manual
7
User Manuals and Help
7
Service Manual
7
Instrument Security Procedures
8
Basic Safety Instructions
8
Data Sheets and Brochures
8
Release Notes and Open Source Acknowledgment (OSA)
8
Application Notes, Application Cards, White Papers, Etc
9
Preparing for Use
10
Putting into Operation
10
EMI Suppression
11
Unpacking and Checking the Instrument
12
Accessory List
12
Placing or Mounting the Instrument
12
Connecting AC Power
15
Turning the Instrument on and off
15
Functional Check
17
Checking the Supplied Options and Licenses
17
Connecting USB Devices
18
Setting up a Network (LAN) Connection
18
Connecting the Instrument to the Network
19
Instrument Tour
21
Front Panel Tour
21
Touchscreen
22
Utility Keys
24
On/Standby
24
Function Keys
24
Keypad
25
Navigation Controls
25
Rotary Knob
25
Editing Keys
25
Navigation Keys
26
Display Keys
27
USB Connector
27
SD Card Slot
27
5.1.10 Sensor
27
Rf 50 Ω
28
5.1.12 Pulse Signal Connectors
29
5.1.13 LF Modulation Connectors
30
5.1.14 Clock Synthesizer Connectors
30
Rear Panel Tour
30
Connectors
32
Trying out the Instrument
35
Generating an Unmodulated Carrier
35
Generating an RF Frequency Sweep Signal
39
Saving and Recalling Settings
41
Instrument Control
45
Possible Ways to Operate the Instrument
45
Means of Manual Interaction
46
Understanding the Display Information
46
Status Bar
47
Tile Diagram
47
Taskbar
48
Advertisement
Advertisement
Related Products
R&S SMB100A
R&S SGS100A
R&S SMW-K548
R&S SMM100A
R&S SGU100A
R&S SMA100A
R&S SMW-K108
R&S SMW-K106
R&S SMCVB-K167
R&S SMCV100B
R&S Categories
Measuring Instruments
Test Equipment
Accessories
Power Supply
Portable Generator
More R&S Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL