Motorcycle starts reverse running but stops immediately

1. Voltage to Starter Motor Signal Line Continuity Inspection
Check for a blown No. 11 RVS fuse A (5 A).
Check the starter/reverse motor (No. 12) circuit at the cruise/reverse control module (page 19-39).
Is there continuity?
NO
YES
System enters the reverse mode before all reverse running conditions are satisfied
1. Side Stand Switch and Oil Pressure Switch Signal Line Continuity Inspection
Check the side stand switch (No. 11) and oil pressure switch (No. 48) circuits at the cruise/reverse
control module (page 19-39).
Is the continuity correct?
NO
YES
19-16
– • Check for open circuit in the Pink wire between starter relay switch B and reverse fuse A
in the fuse box.
• Check for an open circuit in the Pink/white wire between the cruise/reverse control mod-
ule and reverse fuse B in the fuse box.
– • Loose or poor contact of the cruise/reverse control module connectors.
• Faulty cruise/reverse control module.
– • Check for a short circuit in the Green/white wire between the cruise/reverse control mod-
ule and side stand switch.
• Faulty side stand switch.
• Check for an open circuit in the Blue or Blue/red wire between the cruise/reverse control
module and oil pressure switch, or faulty diode.
• Faulty oil pressure switch.
– Faulty cruise/reverse control module.