M800V/M80V Series PLC Programming Manual (2/2)
15 Multi-axis and Multi-part System
15.4 Synchronization Between Part Systems OFF
15.4.2 Relation with Other Functions
Sub part system control II
When performing sub part system calls, signals such as the cutting feed override and rapid traverse override signals in sub
part systems are used as main part system signals, but the synchronization between part systems OFF (MSYNC) signal
and the dry run disabled (DRNC) signal are used as sub part system signals.
When a sub part system completes, #3003 and #3004 are reset to "0".
15.4.3 Precautions
Functions are disabled when system variables or PLC signals are turned ON.
Part system synchronization
System variable is ON
System variable is OFF
Dry run disable operates in the same manner.
15.4.4 System Variable
bit7
bit6
bit5
#3003
NOTE: #3003 is set to "0" after reset.
bit7
bit6
bit5
#3004
NOTE: #3004 is set to "0" after reset.
IB-1501668-B
PLC sign is ON
Function disabled
Function disabled
bit4
bit3
bit2
bit1
bit0
bit4
bit3
bit2
bit1
902
PLC signal is OFF
Function disabled
Function enabled
"1": Single block stop suppression, "0": No stop suppression
"1": No M function finish signal, "0": M function finish signal
"1": Program check reverse run prohibited, "0": Reverse run
"1": Synchronization between part systems OFF, "0": ON
Not used
bit0
"1": Automatic operation pause ON, "0": OFF
"1": Cutting override OFF, "0": ON
"1": G09 check OFF, "0": ON
Not used
"1": Dry run invalid, "0": Valid
Not used