8 Function Instructions
8.6 Logical Operation Instructions
DXNR
 Conducts a non-exclusive logical sum operation on each bit of the 32-bit data of the device designated by "S1" and the 32-
bit data of the device designated by "S2", and stores the results in the device designated by "D".
0 1 0 1
Before execution S1
0 1 1
Before execution S2
After execution D
1 1
 For the bit device, the bits corresponding the digits other than the designated digit are handled as "0" in the operation.
32 bit
S1+1
S1
0 1 0 1 0 1
XNR
S2+1
S2
0 1 1
0
0
0 1
D+1
D
0 0
1 1
0 0 0 0
0 1 0 1
1
0 1
0
1 1
0 0
277