4 Explanation of Devices

4.4 Detailed Explanation of Devices

4.4 Detailed Explanation of Devices

4.4.1 Input/Output X, Y

Input/output X and Y are windows for executing communication with the PLC and external device or controller.
Input X
 This issued commands or data from an external device such as a push-button, changeover switch, limit switch or digital
switch to the PLC.
 Assuming that there is a hypothetical relay Xn built-in the PLC per input point, the program uses the "A" contact and "B"
contact of that Xn.
 There is no limit to the number of "A" contacts and "B" contacts of the input Xn that can be used in the program.
Hypothetical relay
PB1
LS2
PB16
Input circuit
 The input No. is expressed with a hexadecimal.
Output Y
 This outputs the results of the program control to the solenoid, magnetic switch, signal lamp or digital indicator, etc.
 The output (Y) can be retrieved with the equivalent of one "A" contact.
 There is no limit to the number of "A" contacts and "B" contacts of the output Yn that can be used in the program.
PLC
Y10
Y10
Y10
Program
 The output No. is expressed with a hexadecimal.