Power Consumption Monitor Setting - Mitsubishi Electric M800VW Series Programming Manual

Plc programming
Hide thumbs Also See for M800VW Series:
Table of Contents

Advertisement

M800V/M80V Series PLC Programming Manual (2/2)
14 PLC Help Function
14.40 Power Consumption Computation

14.40.2 Power Consumption Monitor Setting

When you calculate the present power consumption, accumulated power consumption 1 to 4 or accumulated power
consumption history, you need to set the following parameters, R registers and control data (X and Y devices).
The data to set and the control data are listed as follows.
Setting data
Parameter
Parameter No.
Base common
#1371
#1372
#1392
#1393
Axis spec.
#2189
Spindle spec.
#3146
#3147
#3168
Spindle
#13018
#13028
#13134
#13228
[R register (PLC -> NC)]
Parameter No.
Abbrev
R304,5
NDPC
R306,7
DFPCC
Control data
[X device (NC -> PLC)]
Parameter No.
Abbrev
X700 to X703
IPCEI1 to 4
X708 to X70B
IPCCC1 to 4 Clearing consumption accumulation 1 to 4 complete
[Y device (PLC -> NC)]
Parameter No.
Abbrev
Y700 to Y703
IPCC1 to 4
Y724 to Y727
IPCE1 to 4
Register name
Power consumption accumulation interval [hr]
Fixed drive system power consumption [W]
Power consumption accumulation start time [time]
Efficiency for power consumption computation [%]
Stall torque for power consumption [N ・ m]
Short-time rated output for power consumption (L-
coil) [W]
Short-time rated output for power consumption (H-
coil) [W]
Stall torque of spindle-mode servo motor for power
computation [N ・ m]
(SP018/bit5) Coil switch function ON/OFF
(SP028) Speed detection set value [r/min]
(SP134) Base speed [r/min]
(SP228/bit0 to 2) Load display selection
Device name
Consumption of devices other than drive system [W]
Drive system's fixed consumption correction [W]
Device name
Consumption accumulation ON 1 to 4
Device name
Clearing consumption accumulation 1 to 4
Enable consumption accumulation 1 to 4
Present pow-
er consump-
tion
-
-
Present pow-
er consump-
tion
Present pow-
er consump-
tion
-
-
Present pow-
er consump-
tion
-
-
885
Need to set
Accumulated
Accumulated
power con-
power con-
sumption 1 to
sumption his-
4
tory
-
Need to set
Accumulated
Accumulated
power con-
power con-
sumption 1 to
sumption his-
4
tory
Need to set
Accumulated
Accumulated
power con-
power con-
sumption 1 to
sumption his-
4
tory
-
-
Need to set
Accumulated
Accumulated
power con-
power con-
sumption 1 to
sumption his-
4
tory
-
-
IB-1501668-B