14.34.3.5 Initial Parameter Settings: Setting Position Switches (#12870 to #12900)

Set the position switch area. Fifteen types of position switches, PSW1 to PSW15, can be set.
Parame-
Abbreviation
ter No.
12870
aux_PSWcheck
PSW detection method
12871
aux_PSW1dog1
PSW1 area setting 1
12872
aux_PSW1dog2
PSW1 area setting 2
12873
aux_PSW2dog1
PSW2 area setting 1
12874
aux_PSW2dog2
PSW2 area setting 2
12875
aux_PSW3dog1
PSW3 area setting 1
12876
aux_PSW3dog2
PSW3 area setting 2
12877
aux_PSW4dog1
PSW4 area setting 1
12878
aux_PSW4dog2
PSW4 area setting 2
12879
aux_PSW5dog1
PSW5 area setting 1
12880
aux_PSW5dog2
PSW5 area setting 2
12881
aux_PSW6dog1
PSW6 area setting 1
12882
aux_PSW6dog2
PSW6 area setting 2
12883
aux_PSW7dog1
PSW7 area setting 1
12884
aux_PSW7dog2
PSW7 area setting 2
12885
aux_PSW8dog1
PSW8 area setting 1
12886
aux_PSW8dog2
PSW8 area setting 2
12887
aux_PSW9dog1
PSW9 area setting 1
12888
aux_PSW9dog2
PSW9 area setting 2
12889
aux_PSW10dog1
PSW10 area setting 1
12890
aux_PSW10dog2
PSW10 area setting 2
12891
aux_PSW11dog1
PSW11 area setting 1
12892
aux_PSW11dog2
PSW11 area setting 2
12893
aux_PSW12dog1
PSW12 area setting 1
12894
aux_PSW12dog2
PSW12 area setting 2
12895
aux_PSW13dog1
PSW13 area setting 1
12896
aux_PSW13dog2
PSW13 area setting 2
12897
aux_PSW14dog1
PSW14 area setting 1
12898
aux_PSW14dog2
PSW14 area setting 2
12899
aux_PSW15dog1
PSW15 area setting 1
12900
aux_PSW15dog2
PSW15 area setting 2
Parameter name
Set this parameter in hexadecimal format. The bits that are not explained here
must be set to "0".
bit
bit
0
0
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
9
A
A
B
B
C
C
D
D
E
E
F
F
When the machine is positioned at the area determined by
the area settings 1 and 2, the position switch of the corre-
sponding No. will turn ON.
Whether the value of setting 1 is larger than setting 2 (or
vice versa) does not affect the position switch operation.
For rotation axes, the output turns ON in the area excluding
0.000 degree.
Explanations
Position switch
Position switch
Details in "0" setting
Details in "0" setting
PSW1
PSW1
PSW2
PSW2
PSW3
PSW3
PSW4
PSW4
PSW5
PSW5
PSW6
PSW6
PSW7
PSW7
The position switch output will be
The position switch output will be
PSW8
PSW8
judged by the machine position of
judged by the machine position of
PSW9
PSW9
the command system.
the command system.
PSW10
PSW10
PSW11
PSW11
PSW12
PSW12
PSW13
PSW13
PSW14
PSW14
PSW15
PSW15
853
Setting range
(unit)
Details in "1" sett ing
Details in "1" sett ing
The position switch output will be
The position switch output will be
judged by machine feedback
judged by machine feedback
position (actual position).
position (actual position).
-99999.999 to
99999.999°(mm)