Mitsubishi Electric M800VW Series Programming Manual page 464

Plc programming
Hide thumbs Also See for M800VW Series:
Table of Contents

Advertisement

M800V/M80V Series PLC Programming Manual (1/2)
9 Exclusive Instructions
9.1 ATC Exclusive Instruction
Writing the tool data
Instead of setting tool No. through the setting and display unit, the tool No. is entered to each magazine No. set through PLC
program.
ACT
S.ATC K10 R9800 R10610 M10
R9800
9840
R9801
9845
R9802
----
R9840
3
R9845
1234
R10615
2
R10700
1000(0)
R10701
1001(1)
10
R10702
1002(2)
MG1
:
1003(3)
:
(4)
:
(5)
:
(6)
:
:
(7)
:
R10708
1008(8)
R10709
1009(9)
Note
(1) When pointer is not used, R10615 should be set to "zero".
(Example)
MOV K0 R10615
R No. having magazine No. to which data is written
R No. where data to be written is stored
Magazine No. to which data is written
Data to be written
Pointer
8
9
9
MG0
1
2
3
2
Data "1234" is written to magazine No. 3 .
3
4
4
5
6
5
6
7
8
7
Magazine starts from "0"
Magazine starts from "1"
443
IB-1501667-B