M800V/M80V Series PLC Programming Manual (2/2)
14 PLC Help Function
14.34 PLC Axis Indexing

14.34.3.2 Initial Parameter Settings: Setting the Control Parameter 1

Set each control parameter.
#
Abbreviation
Parameter name
aux_Cont1
Control parameter
12802
(PR)
1
Bit
Details in "0" setting
0
1
2
Automatic set position reached sig-
3
nal does not interlock with Opera-
tion start signal
Automatic set position reached sig-
4
nal is turned ON again
Station No. Output within fixed po-
5
sition
6
7
8
Rotation direction determined by
9
operation control signal (DIR)
A
B
C
D
Rotation direction in operation con-
E
trol signal (DIR) or in the shortcut
direction
Stopper direction is in the position-
F
ing direction
Explanations
Set this parameter in hexadecimal format. The bits that are not explained here must be
set to "0".
(Refer to the table below.)
Details in "1" setting
Automatic set position reached signal
interlocks with Operation start signal
Automatic set position reached signal
isn't turned ON again
Station No. Constantly output
Rotation direction in the shortcut di-
rection
Rotation direction in the arbitrary po-
sition command sign direction
Stopper direction is in the sign direc-
tion of the stopper amount
843
Setting range
(unit)
IB-1501668-B