M800V/M80V Series PLC Programming Manual (2/2)
16 External PLC link
16.1 CC-Link
Ver.2 mode
 Ver.2 remote input and remote output
Master station
Remote input RX
RX F to RX 0
For station
No. 1
RX 1F to RX 10
RX 2F to RX 20
For station
No. 2
RX 3F to RX 30
RX 4F to RX 40
For station
No. 3
RX 5F to RX 50
For station
RX 6F to RX 60
No. 4
RX 7F to RX 70
For station
No. 5
RX 8F to RX 80
[Ver.2 RX/RY]
Master station <- Local station/Remote device station/Remote I/O station
 Master station
- The input status from the local station (RY), remote device station and remote I/O station (RX) is stored.
- The number of used points per station changes depending on the number of occupied stations and the extended cyclic
setting. (Refer to "16.1.1 Performance Specifications".)
- For remote I/O station, the number of used points can be set to 8 points, 16 points, or 32 points with parameter.
 Local station
- Data to be sent to the master station is stored in the remote output (RY) of the address corresponding to the host station
number.
- The input status from the remote device station, remote I/O station (RX) and other remote local stations is stored.
- The number of used points per station changes depending on the number of occupied stations and the extended cyclic
setting. (Refer to "16.1.1 Performance Specifications".)
- For remote I/O station, the number of used points can be set to 8 points, 16 points, or 32 points with parameter of the
master station.
Note
(1) Refer to "CC-Link Specifications manual" (BNP-C3072-089) on parameter setting.
IB-1501668-B
Local station
Remote device station
(Station No.1 : Occupied
(Station No.2 : Occupied
1 station, set to "Double")
2 stations, set to "Single")
Remote output RY
Remote output RY
RY F to RY 0
RY 1F to RY 10
RY 2F to RY 20
RX0F to RX00
RY 3F to RY 30
RX1F to RX10
RY 4F to RY 40
RX2F to RX20
RY 5F to RY 50
RX3F to RX30
RY 6F to RY 60
RY 7F to RY 70
RY 8F to RY 80
918
Remote I/O station (Station No.4 :
Local station
Occupied 1 station, set to "Single")
(Station No.5 : Occupied
(8 points + 8 points reserved)
1 station, set to "Single")
Remote input RX
RY F to RY 0
RY 1F to RY 10
RY 2F to RY 20
RY 3F to RY 30
RY 4F to RY 40
RY 5F to RY 50
RY 6F to RY 60
X07 to X00
RY 7F to RY 70
RY 8F to RY 80
The last two bits of the local station cannot be used.