14 PLC Help Function
14.4 Manual Speed Clamp

14.4.3 Relation with Other Functions

The manual feed speed clamp is invalid in the following functions.
 Manual reference position return (dog-type)
 Automatic dog-less type reference position return
 Manual arbitrary feed

14.4.4 Precautions

(1) During jog feed, handle feed, incremental feed or manual reference position return (high-speed), the manual speed clamp
ON/OFF switch by the "Manual speed clamp ON" signal (MCLMP: YC76) is immediately reflected regardless of the axis
movement or its stop.
Rapid traverse speed (rapid)
Manual feed clamp speed
Manual speed clamp ON signal
(2) The manual speed clamp also become effective for the jog or handle feed in the manual/auto simultaneous or handle
interrupt in automatic operation mode.
(3) When "#2641 m_clamp" (Manual feed clamp speed) is greater than "#2641 m_clamp" (Manual feed clamp speed),
"#2001 rapid" (Rapid traverse speed) is applied regardless of ON/OFF of the manual speed clamp.
(4) The manual feed clamp speed is enabled by the "Manual speed clamp ON" signal (MCLMP: YC76) only for the basic con-
figuration axes of the part system.