M800V/M80V Series PLC Programming Manual (2/2)
14 PLC Help Function
14.23 PLC Switches

14.23.4 Switch Name Preparation

Prepare PLC switch names by using a text file format or PLC development software (GX Developer).
According to the description format, set the number of characters for one switch name and the number of points for switches,
then prepare switch name data. The maximum length of a switch name is 14 characters. A maximum of 96 switch names (#1
to #96) can be prepared regardless of the number of switches.
Note
(1) With 32 points of switches, a maximum of 32 points are displayed on the PLC switch screen display and are available for
input signal reversing with the PLC switch reverse signals.
For details, refer to "PLC Development Manual".

14.23.5 Non-Display of the PLC Switch

A PLC switch name can be hidden.
To hide the PLC switch name, turn ON the "PLC switch non-display" signal (ZR) corresponding to each switch name.
When the PLC switch name is hidden, the switch No. movement cursor can still move to the hidden switch No., but the menu
keys [ON] and [OFF] are grayed out and cannot be turned ON/OFF.
Even when you turn ON the "PLC switch reversed display" signal Y of the hidden switch No., the switch name is not
highlighted.