M800V/M80V Series PLC Programming Manual (2/2)
14 PLC Help Function
14.36 External Search
External search status
The correspondence of the external search status values and details output from the NC based on the external search is
shown below.
Status value
0
Normally finished
1
Operation search is being carried out
Search was attempted while external search was in-
2
valid.
Any non-existent or inoperative device has been
3
designated.
4
The program file is not designated
The block with the designated program No., se-
5
quence No. or block No. was not found
6
The designated device does not support the batch
7
program search across all part systems.
Signal name
External search:
Program return completed
External search:
Program return complete status
 Program return completed
This signal turns ON when the program return is completed by inputting the program return signal. This also turns ON when
an error occurs.
This signal turns OFF when the program return signal is turned OFF from the user PLC.
 Program return complete status
This signal outputs the status of when the program return completed signal is ON.
Details
Wait for other function's operation search to finish
before searching.
Stop the program before searching.
Cancel the emergency stop or reset before
searching.
Confirm the presence of the device, and that the
device is within the specifications
Designate the program No. or sequence No.
Check the machining program.
-
Designate a device which supports the batch pro-
gram search across all part systems.
1st part
2nd part
3rd part
system
system
system
XCEA
XE2A
XF6A
R501
R701
R901
869
Remedy
-
-
Part system No.
4th part sys-
5th part
6th part
tem
system
system
X10AA
X11EA
X132A
R1101
R1301
R1501
7th part
8th part sys-
system
tem
X146A
X15AA
R1701
R1901